{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/61916"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/61916","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Design, fabrication, and characterization of controllable conducting polymer actuation systems","abstract":"The geometric, hierarchal, multifunctional composition of mammalian skeletal muscle and the neuromuscular system consists of actuation elements, length sensors, force sensors, localized energy storage, controlled energy delivery, computational components, and intercommunication pathways. Conducting polymer materials are versatile enough to perform all of the above functions. This work explores the design, characterization, and implementation of three conducting polymer components in building artificial muscle actuation systems: actuators, length sensors, and energy storage. The first systematic strain characterization of polypyrrole actuators at voltages above 1 V for a frequency range of 0.01 Hz to 100 Hz is reported. Material, mechanical, and electrical properties of polypyrrole length sensors are evaluated over the same frequency range. Polypyrrole supercapacitors are evaluated as a function of dopant, electrolyte, geometry, and mass, enabling the determination of their capacitance, charge-discharge lifetime, and self-discharge. Fabrication techniques for combining multiple conducting polymer components (actuators, length sensors, and energy storage elements) by means of electrically insulated, mechanical attachments are developed and demonstrated. An all-polymer, open loop linear contractile actuation system is presented, along with the first conducting polymer powered conducting polymer actuators, and the first tripolymer system. These results build a foundation upon which large, scalable, self-powered, all polymer electro-chemo-mechanical actuation systems can be developed for a future set of conducting polymer artificial muscle systems.","abstract_html":"The geometric, hierarchal, multifunctional composition of mammalian skeletal muscle and the neuromuscular system consists of actuation elements, length sensors, force sensors, localized energy storage, controlled energy delivery, computational components, and intercommunication pathways. Conducting polymer materials are versatile enough to perform all of the above functions. This work explores the design, characterization, and implementation of three conducting polymer components in building artificial muscle actuation systems: actuators, length sensors, and energy storage. The first systematic strain characterization of polypyrrole actuators at voltages above 1 V for a frequency range of 0.01 Hz to 100 Hz is reported. Material, mechanical, and electrical properties of polypyrrole length sensors are evaluated over the same frequency range. Polypyrrole supercapacitors are evaluated as a function of dopant, electrolyte, geometry, and mass, enabling the determination of their capacitance, charge-discharge lifetime, and self-discharge. Fabrication techniques for combining multiple conducting polymer components (actuators, length sensors, and energy storage elements) by means of electrically insulated, mechanical attachments are developed and demonstrated. An all-polymer, open loop linear contractile actuation system is presented, along with the first conducting polymer powered conducting polymer actuators, and the first tripolymer system. These results build a foundation upon which large, scalable, self-powered, all polymer electro-chemo-mechanical actuation systems can be developed for a future set of conducting polymer artificial muscle systems.","abstract_has_math":false,"creators":["Paster, Eli (Eli Travis)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Ian Hunter."],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010","date_published":"2010","updated_at":"2026-07-22T22:20:52Z","subjects":["Mechanical Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/61916","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ian Hunter."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Paster, Eli (Eli Travis)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-03-24T20:26:17Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-03-24T20:26:17Z"]},{"key":"dc:date.issued","label":"Date","values":["2010"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/61916"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2010.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 144-148)."]},{"key":"dc:description.abstract","label":"Abstract","values":["The geometric, hierarchal, multifunctional composition of mammalian skeletal muscle and the neuromuscular system consists of actuation elements, length sensors, force sensors, localized energy storage, controlled energy delivery, computational components, and intercommunication pathways. Conducting polymer materials are versatile enough to perform all of the above functions. This work explores the design, characterization, and implementation of three conducting polymer components in building artificial muscle actuation systems: actuators, length sensors, and energy storage. The first systematic strain characterization of polypyrrole actuators at voltages above 1 V for a frequency range of 0.01 Hz to 100 Hz is reported. Material, mechanical, and electrical properties of polypyrrole length sensors are evaluated over the same frequency range. Polypyrrole supercapacitors are evaluated as a function of dopant, electrolyte, geometry, and mass, enabling the determination of their capacitance, charge-discharge lifetime, and self-discharge. Fabrication techniques for combining multiple conducting polymer components (actuators, length sensors, and energy storage elements) by means of electrically insulated, mechanical attachments are developed and demonstrated. An all-polymer, open loop linear contractile actuation system is presented, along with the first conducting polymer powered conducting polymer actuators, and the first tripolymer system. These results build a foundation upon which large, scalable, self-powered, all polymer electro-chemo-mechanical actuation systems can be developed for a future set of conducting polymer artificial muscle systems."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:title","label":"Title","values":["Design, fabrication, and characterization of controllable conducting polymer actuation systems"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ian Hunter."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Paster, Eli (Eli Travis)"],"dc:date.accessioned":["2011-03-24T20:26:17Z"],"dc:date.available":["2011-03-24T20:26:17Z"],"dc:date.issued":["2010"],"dc:description":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2010.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 144-148)."],"dc:description.abstract":["The geometric, hierarchal, multifunctional composition of mammalian skeletal muscle and the neuromuscular system consists of actuation elements, length sensors, force sensors, localized energy storage, controlled energy delivery, computational components, and intercommunication pathways. Conducting polymer materials are versatile enough to perform all of the above functions. This work explores the design, characterization, and implementation of three conducting polymer components in building artificial muscle actuation systems: actuators, length sensors, and energy storage. The first systematic strain characterization of polypyrrole actuators at voltages above 1 V for a frequency range of 0.01 Hz to 100 Hz is reported. Material, mechanical, and electrical properties of polypyrrole length sensors are evaluated over the same frequency range. Polypyrrole supercapacitors are evaluated as a function of dopant, electrolyte, geometry, and mass, enabling the determination of their capacitance, charge-discharge lifetime, and self-discharge. Fabrication techniques for combining multiple conducting polymer components (actuators, length sensors, and energy storage elements) by means of electrically insulated, mechanical attachments are developed and demonstrated. An all-polymer, open loop linear contractile actuation system is presented, along with the first conducting polymer powered conducting polymer actuators, and the first tripolymer system. These results build a foundation upon which large, scalable, self-powered, all polymer electro-chemo-mechanical actuation systems can be developed for a future set of conducting polymer artificial muscle systems."],"dc:description.degree":["S.M."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/61916"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Design, fabrication, and characterization of controllable conducting polymer actuation systems"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:20:52Z"}