{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/61268"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/61268","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Measurement of work function in CF₄ gas","abstract":"CF4 gas is useful in many applications, especially as a drift gas in particle detection chambers. In order to make accurate measurements of incident particles the properties of the drift gas must be well understood. An important property of CF4 which is important for determining particle energy in detectors, the work function, is disputed and not well known. This thesis measures the work function of CF4 gas for use in the Dark Matter Time Projection Chamber as well as all experiments that use CF4 as a drift gas. This was accomplished by bombarding CF4 in a drift chamber and ionizing it, then collecting the ionized electrons on an anode. The work function was found to be 33.8 ± 0.4 eV. This value was then crosschecked against P10, which is well understood.","abstract_html":"CF4 gas is useful in many applications, especially as a drift gas in particle detection chambers. In order to make accurate measurements of incident particles the properties of the drift gas must be well understood. An important property of CF4 which is important for determining particle energy in detectors, the work function, is disputed and not well known. This thesis measures the work function of CF4 gas for use in the Dark Matter Time Projection Chamber as well as all experiments that use CF4 as a drift gas. This was accomplished by bombarding CF4 in a drift chamber and ionizing it, then collecting the ionized electrons on an anode. The work function was found to be 33.8 ± 0.4 eV. This value was then crosschecked against P10, which is well understood.","abstract_has_math":false,"creators":["Wolfe, Ian C"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Physics.","school":null,"contributors":[],"advisors":["Denis Dujmic and Peter Fisher."],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010","date_published":"2010","updated_at":"2026-07-22T22:20:52Z","subjects":["Physics."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/61268","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Denis Dujmic and Peter Fisher."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Physics."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Physics."]},{"key":"dc:creator","label":"Author","values":["Wolfe, Ian C"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-02-23T14:39:09Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-02-23T14:39:09Z"]},{"key":"dc:date.issued","label":"Date","values":["2010"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/61268"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Physics, 2010.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 71)."]},{"key":"dc:description.abstract","label":"Abstract","values":["CF4 gas is useful in many applications, especially as a drift gas in particle detection chambers. In order to make accurate measurements of incident particles the properties of the drift gas must be well understood. An important property of CF4 which is important for determining particle energy in detectors, the work function, is disputed and not well known. This thesis measures the work function of CF4 gas for use in the Dark Matter Time Projection Chamber as well as all experiments that use CF4 as a drift gas. This was accomplished by bombarding CF4 in a drift chamber and ionizing it, then collecting the ionized electrons on an anode. The work function was found to be 33.8 ± 0.4 eV. This value was then crosschecked against P10, which is well understood."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:title","label":"Title","values":["Measurement of work function in CF₄ gas"]}]}],"canonical_facts":{"dc:contributor.advisor":["Denis Dujmic and Peter Fisher."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Physics."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Physics."],"dc:creator":["Wolfe, Ian C"],"dc:date.accessioned":["2011-02-23T14:39:09Z"],"dc:date.available":["2011-02-23T14:39:09Z"],"dc:date.issued":["2010"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Physics, 2010.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 71)."],"dc:description.abstract":["CF4 gas is useful in many applications, especially as a drift gas in particle detection chambers. In order to make accurate measurements of incident particles the properties of the drift gas must be well understood. An important property of CF4 which is important for determining particle energy in detectors, the work function, is disputed and not well known. This thesis measures the work function of CF4 gas for use in the Dark Matter Time Projection Chamber as well as all experiments that use CF4 as a drift gas. This was accomplished by bombarding CF4 in a drift chamber and ionizing it, then collecting the ionized electrons on an anode. The work function was found to be 33.8 ± 0.4 eV. This value was then crosschecked against P10, which is well understood."],"dc:description.degree":["S.B."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/61268"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Physics."],"dc:title":["Measurement of work function in CF₄ gas"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:20:52Z"}