{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/61245"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/61245","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Low-field classroom nuclear magnetic resonance system","abstract":"The goal of this research was to develop a Low-field Classroom NMR system that will enable hands-on learning of NMR and MRI concepts in a Biological-Engineering laboratory course. A permanent magnet system, designed using finite-element modeling software, was built to produce a static field of Bo = 0.133 Tesla. A single coil was used for both transmitting the excitation pulses and detecting the NMR signal. The probe circuit is essentially an LC tank with a tunable resonant frequency. An FPGA is used to produce the excitation pulses and process the received NMR signals. This research has led to the ability to observe Nuclear Magnetic Resonance. 'Spin- Lattice' and 'Spin-Spin' relaxation times of glycerin samples can easily be measured. Future work will allow further MRI exploration by incorporating gradient magnetic field coils.","abstract_html":"The goal of this research was to develop a Low-field Classroom NMR system that will enable hands-on learning of NMR and MRI concepts in a Biological-Engineering laboratory course. A permanent magnet system, designed using finite-element modeling software, was built to produce a static field of Bo = 0.133 Tesla. A single coil was used for both transmitting the excitation pulses and detecting the NMR signal. The probe circuit is essentially an LC tank with a tunable resonant frequency. An FPGA is used to produce the excitation pulses and process the received NMR signals. This research has led to the ability to observe Nuclear Magnetic Resonance. &#x27;Spin- Lattice&#x27; and &#x27;Spin-Spin&#x27; relaxation times of glycerin samples can easily be measured. Future work will allow further MRI exploration by incorporating gradient magnetic field coils.","abstract_has_math":false,"creators":["Zimmerman, Clarissa Lynette"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.","school":null,"contributors":[],"advisors":["Edward S. Boyden."],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010","date_published":"2010","updated_at":"2026-07-22T22:22:30Z","subjects":["Electrical Engineering and Computer Science."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/61245","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Edward S. Boyden."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Zimmerman, Clarissa Lynette"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-02-23T14:35:41Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-02-23T14:35:41Z"]},{"key":"dc:date.issued","label":"Date","values":["2010"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/61245"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2010.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 109)."]},{"key":"dc:description.abstract","label":"Abstract","values":["The goal of this research was to develop a Low-field Classroom NMR system that will enable hands-on learning of NMR and MRI concepts in a Biological-Engineering laboratory course. A permanent magnet system, designed using finite-element modeling software, was built to produce a static field of Bo = 0.133 Tesla. A single coil was used for both transmitting the excitation pulses and detecting the NMR signal. The probe circuit is essentially an LC tank with a tunable resonant frequency. An FPGA is used to produce the excitation pulses and process the received NMR signals. This research has led to the ability to observe Nuclear Magnetic Resonance. 'Spin- Lattice' and 'Spin-Spin' relaxation times of glycerin samples can easily be measured. Future work will allow further MRI exploration by incorporating gradient magnetic field coils."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.Eng."]},{"key":"dc:title","label":"Title","values":["Low-field classroom nuclear magnetic resonance system"]}]}],"canonical_facts":{"dc:contributor.advisor":["Edward S. Boyden."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."],"dc:creator":["Zimmerman, Clarissa Lynette"],"dc:date.accessioned":["2011-02-23T14:35:41Z"],"dc:date.available":["2011-02-23T14:35:41Z"],"dc:date.issued":["2010"],"dc:description":["Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2010.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 109)."],"dc:description.abstract":["The goal of this research was to develop a Low-field Classroom NMR system that will enable hands-on learning of NMR and MRI concepts in a Biological-Engineering laboratory course. A permanent magnet system, designed using finite-element modeling software, was built to produce a static field of Bo = 0.133 Tesla. A single coil was used for both transmitting the excitation pulses and detecting the NMR signal. The probe circuit is essentially an LC tank with a tunable resonant frequency. An FPGA is used to produce the excitation pulses and process the received NMR signals. This research has led to the ability to observe Nuclear Magnetic Resonance. 'Spin- Lattice' and 'Spin-Spin' relaxation times of glycerin samples can easily be measured. Future work will allow further MRI exploration by incorporating gradient magnetic field coils."],"dc:description.degree":["M.Eng."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/61245"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["Low-field classroom nuclear magnetic resonance system"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:22:30Z"}