{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/60207"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/60207","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Design and characterization of a compliant-joint robotic jumping leg","abstract":"Biological systems employ compliant joints to allow robust contact with the surroundings and to increase locomotive efficiency. In this experiment, we designed a three-link robotic leg with a compliant calf tendon that was acutated by a DC motor at the hip and measured the effect of compliance on the force profile and energy consumption for a single jump. The lengths of the femur, tibia, and foot were 150 mm, 210 mm, and 60 mm respectively. Overall vertical leg stiffness was varied from 472 N/m to 3980 N/m. Using a 40 degree angle ramp for the motor acutation profile, adding compliance tended to distribute force over time at a smaller magnitude which resulted in longer contact time with the ground. Total impulse was found to vary and peaked at a value of 3.42 Ns for a overall leg stiffness of 1180 N/m. The findings suggest that these systems can be optimized for performance by tuning the stiffness of compliant joints.","abstract_html":"Biological systems employ compliant joints to allow robust contact with the surroundings and to increase locomotive efficiency. In this experiment, we designed a three-link robotic leg with a compliant calf tendon that was acutated by a DC motor at the hip and measured the effect of compliance on the force profile and energy consumption for a single jump. The lengths of the femur, tibia, and foot were 150 mm, 210 mm, and 60 mm respectively. Overall vertical leg stiffness was varied from 472 N/m to 3980 N/m. Using a 40 degree angle ramp for the motor acutation profile, adding compliance tended to distribute force over time at a smaller magnitude which resulted in longer contact time with the ground. Total impulse was found to vary and peaked at a value of 3.42 Ns for a overall leg stiffness of 1180 N/m. The findings suggest that these systems can be optimized for performance by tuning the stiffness of compliant joints.","abstract_has_math":false,"creators":["Wang, Albert Duan"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Sangbae Kim."],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010","date_published":"2010","updated_at":"2026-07-22T22:21:19Z","subjects":["Mechanical Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/60207","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sangbae Kim."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Wang, Albert Duan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-12-06T17:38:05Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-12-06T17:38:05Z"]},{"key":"dc:date.issued","label":"Date","values":["2010"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/60207"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2010.","Cataloged from PDF version of thesis."]},{"key":"dc:description.abstract","label":"Abstract","values":["Biological systems employ compliant joints to allow robust contact with the surroundings and to increase locomotive efficiency. In this experiment, we designed a three-link robotic leg with a compliant calf tendon that was acutated by a DC motor at the hip and measured the effect of compliance on the force profile and energy consumption for a single jump. The lengths of the femur, tibia, and foot were 150 mm, 210 mm, and 60 mm respectively. Overall vertical leg stiffness was varied from 472 N/m to 3980 N/m. Using a 40 degree angle ramp for the motor acutation profile, adding compliance tended to distribute force over time at a smaller magnitude which resulted in longer contact time with the ground. Total impulse was found to vary and peaked at a value of 3.42 Ns for a overall leg stiffness of 1180 N/m. The findings suggest that these systems can be optimized for performance by tuning the stiffness of compliant joints."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:title","label":"Title","values":["Design and characterization of a compliant-joint robotic jumping leg"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sangbae Kim."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Wang, Albert Duan"],"dc:date.accessioned":["2010-12-06T17:38:05Z"],"dc:date.available":["2010-12-06T17:38:05Z"],"dc:date.issued":["2010"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2010.","Cataloged from PDF version of thesis."],"dc:description.abstract":["Biological systems employ compliant joints to allow robust contact with the surroundings and to increase locomotive efficiency. In this experiment, we designed a three-link robotic leg with a compliant calf tendon that was acutated by a DC motor at the hip and measured the effect of compliance on the force profile and energy consumption for a single jump. The lengths of the femur, tibia, and foot were 150 mm, 210 mm, and 60 mm respectively. Overall vertical leg stiffness was varied from 472 N/m to 3980 N/m. Using a 40 degree angle ramp for the motor acutation profile, adding compliance tended to distribute force over time at a smaller magnitude which resulted in longer contact time with the ground. Total impulse was found to vary and peaked at a value of 3.42 Ns for a overall leg stiffness of 1180 N/m. The findings suggest that these systems can be optimized for performance by tuning the stiffness of compliant joints."],"dc:description.degree":["S.B."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/60207"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Design and characterization of a compliant-joint robotic jumping leg"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:19Z"}