{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/60139"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/60139","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Microfluidic devices for analysis of red blood cell mechanical properties","abstract":"Decreased deformability of human red blood cells (RBCs) is both a cause of disease and biomarker for disease (1). To traverse blood capillaries, the biconcave disk-shaped RBC must deform dramatically, since the diameter of the unconstrained RBC is larger than that of the capillaries. If the RBC becomes immobilized in a capillary, hypoxia and tissue injury may result, potentially leading to death. Changes in RBC deformability may be attributable to genetics (e.g. sickle cell anemia (2) and spherocytosis (3)), drug exposure (e.g. pentoxifylline (4)), and disease (e.g. diabetes (5) and malaria (6)). Within the past 15 years, microfabrication techniques have enabled the creation of pores comparable in size and shape to the smallest human capillaries (7) and slits in the spleen (8). We use this microfabrication ability to create devices that analyze and separate RBCs of different deformability. The first device we create is an automated 'deformability cytometer' that measures dynamic mechanical responses of 103~104 individual cells in a cell population. Fluorescence measurements of each cell are simultaneously acquired, resulting in a population-based correlation between biochemical properties (e.g. cell surface markers) and dynamic mechanical deformability. This device is especially applicable to heterogeneous cell populations, and we demonstrate its ability to mechanically characterize a small number of ring-stage malaria-infected RBCs in a large population of healthy RBCs. Next we present a device whose design is based on the architecture of the human spleen. This device is able to continuously separate more deformable from less deformable RBCs. We demonstrate the ability of this device to separate schizont-stage malaria-infected RBCs from healthy RBCs. Together, these devices enable the analysis and separation of single-RBCs based on deformability.","abstract_html":"Decreased deformability of human red blood cells (RBCs) is both a cause of disease and biomarker for disease (1). To traverse blood capillaries, the biconcave disk-shaped RBC must deform dramatically, since the diameter of the unconstrained RBC is larger than that of the capillaries. If the RBC becomes immobilized in a capillary, hypoxia and tissue injury may result, potentially leading to death. Changes in RBC deformability may be attributable to genetics (e.g. sickle cell anemia (2) and spherocytosis (3)), drug exposure (e.g. pentoxifylline (4)), and disease (e.g. diabetes (5) and malaria (6)). Within the past 15 years, microfabrication techniques have enabled the creation of pores comparable in size and shape to the smallest human capillaries (7) and slits in the spleen (8). We use this microfabrication ability to create devices that analyze and separate RBCs of different deformability. The first device we create is an automated &#x27;deformability cytometer&#x27; that measures dynamic mechanical responses of 103~104 individual cells in a cell population. Fluorescence measurements of each cell are simultaneously acquired, resulting in a population-based correlation between biochemical properties (e.g. cell surface markers) and dynamic mechanical deformability. This device is especially applicable to heterogeneous cell populations, and we demonstrate its ability to mechanically characterize a small number of ring-stage malaria-infected RBCs in a large population of healthy RBCs. Next we present a device whose design is based on the architecture of the human spleen. This device is able to continuously separate more deformable from less deformable RBCs. We demonstrate the ability of this device to separate schizont-stage malaria-infected RBCs from healthy RBCs. Together, these devices enable the analysis and separation of single-RBCs based on deformability.","abstract_has_math":false,"creators":["Bow, Hansen Chang"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.","school":null,"contributors":[],"advisors":["Jongyoon Han."],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010","date_published":"2010","updated_at":"2026-07-22T22:21:19Z","subjects":["Electrical Engineering and Computer Science."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/60139","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jongyoon Han."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Bow, Hansen Chang"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-12-06T17:28:10Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-12-06T17:28:10Z"]},{"key":"dc:date.issued","label":"Date","values":["2010"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/60139"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2010.","Cataloged PDF version of thesis.","Includes bibliographical references (p. 118-126)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Decreased deformability of human red blood cells (RBCs) is both a cause of disease and biomarker for disease (1). To traverse blood capillaries, the biconcave disk-shaped RBC must deform dramatically, since the diameter of the unconstrained RBC is larger than that of the capillaries. If the RBC becomes immobilized in a capillary, hypoxia and tissue injury may result, potentially leading to death. Changes in RBC deformability may be attributable to genetics (e.g. sickle cell anemia (2) and spherocytosis (3)), drug exposure (e.g. pentoxifylline (4)), and disease (e.g. diabetes (5) and malaria (6)). Within the past 15 years, microfabrication techniques have enabled the creation of pores comparable in size and shape to the smallest human capillaries (7) and slits in the spleen (8). We use this microfabrication ability to create devices that analyze and separate RBCs of different deformability. The first device we create is an automated 'deformability cytometer' that measures dynamic mechanical responses of 103~104 individual cells in a cell population. Fluorescence measurements of each cell are simultaneously acquired, resulting in a population-based correlation between biochemical properties (e.g. cell surface markers) and dynamic mechanical deformability. This device is especially applicable to heterogeneous cell populations, and we demonstrate its ability to mechanically characterize a small number of ring-stage malaria-infected RBCs in a large population of healthy RBCs. Next we present a device whose design is based on the architecture of the human spleen. This device is able to continuously separate more deformable from less deformable RBCs. We demonstrate the ability of this device to separate schizont-stage malaria-infected RBCs from healthy RBCs. Together, these devices enable the analysis and separation of single-RBCs based on deformability."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:title","label":"Title","values":["Microfluidic devices for analysis of red blood cell mechanical properties"]}]}],"canonical_facts":{"dc:contributor.advisor":["Jongyoon Han."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."],"dc:creator":["Bow, Hansen Chang"],"dc:date.accessioned":["2010-12-06T17:28:10Z"],"dc:date.available":["2010-12-06T17:28:10Z"],"dc:date.issued":["2010"],"dc:description":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2010.","Cataloged PDF version of thesis.","Includes bibliographical references (p. 118-126)."],"dc:description.abstract":["Decreased deformability of human red blood cells (RBCs) is both a cause of disease and biomarker for disease (1). To traverse blood capillaries, the biconcave disk-shaped RBC must deform dramatically, since the diameter of the unconstrained RBC is larger than that of the capillaries. If the RBC becomes immobilized in a capillary, hypoxia and tissue injury may result, potentially leading to death. Changes in RBC deformability may be attributable to genetics (e.g. sickle cell anemia (2) and spherocytosis (3)), drug exposure (e.g. pentoxifylline (4)), and disease (e.g. diabetes (5) and malaria (6)). Within the past 15 years, microfabrication techniques have enabled the creation of pores comparable in size and shape to the smallest human capillaries (7) and slits in the spleen (8). We use this microfabrication ability to create devices that analyze and separate RBCs of different deformability. The first device we create is an automated 'deformability cytometer' that measures dynamic mechanical responses of 103~104 individual cells in a cell population. Fluorescence measurements of each cell are simultaneously acquired, resulting in a population-based correlation between biochemical properties (e.g. cell surface markers) and dynamic mechanical deformability. This device is especially applicable to heterogeneous cell populations, and we demonstrate its ability to mechanically characterize a small number of ring-stage malaria-infected RBCs in a large population of healthy RBCs. Next we present a device whose design is based on the architecture of the human spleen. This device is able to continuously separate more deformable from less deformable RBCs. We demonstrate the ability of this device to separate schizont-stage malaria-infected RBCs from healthy RBCs. Together, these devices enable the analysis and separation of single-RBCs based on deformability."],"dc:description.degree":["Ph.D."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/60139"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["Microfluidic devices for analysis of red blood cell mechanical properties"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:19Z"}