Back to results

Massachusetts Institute of Technology

Dual position locking joint design for a medical walker

Abstract

dc:description.abstract

In this thesis we analyzed a joint created for a medical walker currently in the prototyping stage of development. The walker is designed to help a user stand up from a seated position. The joint holds two legs of the walker together in an 'x' shape. It must be able to lock in two positions and support the full weight of the user while he or she is getting up. We looked at four different locking mechanisms including a spring loaded pull pin, a friction bearing, a clutch, and an electronic solenoid. After weighing the pros and cons of each mechanism we recommend and present a design using the pull pin. In order to determine the strength and deflection of the loaded pin we modeled it both as a cantilevered beam, and a simply supported beam with three points of contact. We compared the hand calculations to FEA of solid models and found that modeling the pin as a simply supported beam is more accurate than the cantilever representation.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Beecher, Eric M
Advisor dc:contributor.advisor
  • Warren P. Seering.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/59895
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/59895

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Beecher, Eric M. Dual position locking joint design for a medical walker. Massachusetts Institute of Technology, 2010. http://hdl.handle.net/1721.1/59895