Back to results

Massachusetts Institute of Technology

Information transmission in the MIMIC II clinical database

Abstract

dc:description.abstract

The promise of the Electronic Medical Record (EMR) to store, retrieve, and communicate medical information effectively for a caregiver team has remained largely unfulfilled since its advent in the late 1960's. Previous studies have cited that the communication function of the EMR is critical to its successful adoption. Based on Mediated Agent Interaction theory, this study proposes a message-based model of transmission of clinical information in the EMR. This model is implemented on an existing ICU clinical database, MIMIC II, to produce a database of transmission events. Three metrics for information transmission are derived from exploratory and object-attribute analyses: transmission volume, duration, and load (or rate). Also derived is a set of features that includes a patient's clinical conditions (with acuity scores and mortality), caregiver type and distribution, care-unit locations, duration of care, and types of clinical records. This list of features is reduced to a set of explanatory variables using correlation and univariate logistic regression. Bayesian Network (BN) models are constructed to predict levels of the transmission metrics. BN models show high prediction accuracy for measuring various levels of messaging volume and load, but marginal accuracy for messaging duration. Results from these methods suggest that the volume of information transmitted in the ICU for adult patients is primarily through charts entered by nurses and respiratory technicians (RTs). The amount of data recorded by RTs increases for patients with higher acuity scores, but transmission from nurses decreases for these patients. The rate at which information is transmitted in the ICU for adult patients is directly related to the rate at which notes and charts are entered, as well as the care-unit location where the data is recorded. Further study is required to investigate factors influencing the length of time information is transmitted in the ICU. This study's findings are based on data recorded by caregivers as clinical observations. Further study is necessary to corroborate these results with clinical communications data, including evidence of reception of clinical information by caregivers. The model proposed by this study may be used as a basis for future research and to discover other patterns of clinical communications.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Engineering Systems Division.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mishra, Rajesh, S.M. Massachusetts Institute of Technology
Advisor dc:contributor.advisor
  • Peter Szolovits and Roy Welsch.

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/59265
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/59265

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Mishra, Rajesh, S.M. Massachusetts Institute of Technology. Information transmission in the MIMIC II clinical database. Massachusetts Institute of Technology, 2010. http://hdl.handle.net/1721.1/59265