In the development of a powered ankle-foot prosthesis, it is desirable to provide the prosthesis with the ability to exhibit human-like dynamics. A simple method for achieving this goal involves trajectory tracking, where a specific target torque trajectory is known, and the controller issues commands to follow the trajectory as closely as possible. However, without a methodology to update the desired trajectory in real time, this type of control scheme is limited in that it cannot adapt to externally-applied disturbances. Adaptation is critical in the field of prosthetics. A prosthesis must be able to adjust to variable terrain and respond to changes in behavior of the wearer. In this thesis, we hypothesize that a powered ankle-foot prosthesis that is controlled using a positive-force- feedback reflex of a Hill-type posterior leg muscle will exhibit biologically-consistent adaptive changes in stance phase behavior across terrain. To evaluate this hypothesis, a controller for a powered ankle-foot prosthesis is advanced that comprises a neuromuscular model consisting of a single, effective plantar flexor muscle with positive force feedback and an effective dorsiflexor consisting of a proportional-derivative impedance controller. Selected parameters of this hybrid controller were optimized to best match the torque-angle relationship of an intact, biological ankle from a weight and height-matched individual with intact limbs. The torque-tracking capabilities of the electromechanical system were evaluated, and a control system was developed to enable the prosthesis to produce human-like ankle mechanics. Clinical trials were performed on a healthy, bilateral amputee study participant at two separate level-ground walking speeds, as well as for ramp ascent and descent walking at self-selected speeds. The neuromuscular reflex model, when used as the basis of the prosthetic controller during these trials, produced ankle torques in qualitative agreement with values from the weight and height-matched individual with intact limbs. This agreement included an impedance modulation in the initial stance period, as well as a biologically consistent trend of increasing prosthesis net work for correspondingly increasing floor inclinations.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Eilenberg, Michael Frederick
Advisor dc:contributor.advisor
  • Hugh Herr.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/58192
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/58192

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Eilenberg, Michael Frederick. A neuromuscular-model based control strategy for powered ankle-foot prostheses. Massachusetts Institute of Technology, 2009. http://hdl.handle.net/1721.1/58192