{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/55148"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/55148","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Development of an Enzyme-Linked ImmunoSorbent Assay (ELISA) with Enhanced Sensitivity in a Nanofluidic System","abstract":"Experimental studies were performed to evaluate the kinetics and equilibrium binding constants of biomolecules in nanofluidic channels. Binding events in the nanochannel were detected using electrical and fluorescence methods. We concluded that antibody-antigen binding constants in nanochannels were similar to experiments performed in microtiter plates at low antigen concentrations; however the bound fraction in nanochannels at high antigen concentration decreased due to steric hindrance. Binding kinetics in nanochannels was limited by convective transport of analytes, instead of diffusion or reaction. We also found that enzymatic reactions in nanochannels were very effective due to short diffusion length and high surface area to volume ratio. A bead based ELISA was developed to exploit the rapid binding reactions in the bulk and efficient enzymatic conversion in the nanochannels. Additionally, electrokinetic concentrators were integrated with multiplexed bead based ELISA to further improve the detection sensitivity of a sandwich immunoassay.","abstract_html":"Experimental studies were performed to evaluate the kinetics and equilibrium binding constants of biomolecules in nanofluidic channels. Binding events in the nanochannel were detected using electrical and fluorescence methods. We concluded that antibody-antigen binding constants in nanochannels were similar to experiments performed in microtiter plates at low antigen concentrations; however the bound fraction in nanochannels at high antigen concentration decreased due to steric hindrance. Binding kinetics in nanochannels was limited by convective transport of analytes, instead of diffusion or reaction. We also found that enzymatic reactions in nanochannels were very effective due to short diffusion length and high surface area to volume ratio. A bead based ELISA was developed to exploit the rapid binding reactions in the bulk and efficient enzymatic conversion in the nanochannels. Additionally, electrokinetic concentrators were integrated with multiplexed bead based ELISA to further improve the detection sensitivity of a sandwich immunoassay.","abstract_has_math":false,"creators":["Cheow, Lih Feng"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.","school":null,"contributors":[],"advisors":["Jongyoon Han."],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009","date_published":"2009","updated_at":"2026-07-22T22:22:26Z","subjects":["Electrical Engineering and Computer Science."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/55148","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jongyoon Han."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Cheow, Lih Feng"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-05-25T20:53:59Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-05-25T20:53:59Z"]},{"key":"dc:date.issued","label":"Date","values":["2009"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/55148"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2009.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 66-68)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Experimental studies were performed to evaluate the kinetics and equilibrium binding constants of biomolecules in nanofluidic channels. Binding events in the nanochannel were detected using electrical and fluorescence methods. We concluded that antibody-antigen binding constants in nanochannels were similar to experiments performed in microtiter plates at low antigen concentrations; however the bound fraction in nanochannels at high antigen concentration decreased due to steric hindrance. Binding kinetics in nanochannels was limited by convective transport of analytes, instead of diffusion or reaction. We also found that enzymatic reactions in nanochannels were very effective due to short diffusion length and high surface area to volume ratio. A bead based ELISA was developed to exploit the rapid binding reactions in the bulk and efficient enzymatic conversion in the nanochannels. Additionally, electrokinetic concentrators were integrated with multiplexed bead based ELISA to further improve the detection sensitivity of a sandwich immunoassay."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:title","label":"Title","values":["Development of an Enzyme-Linked ImmunoSorbent Assay (ELISA) with Enhanced Sensitivity in a Nanofluidic System"]}]}],"canonical_facts":{"dc:contributor.advisor":["Jongyoon Han."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."],"dc:creator":["Cheow, Lih Feng"],"dc:date.accessioned":["2010-05-25T20:53:59Z"],"dc:date.available":["2010-05-25T20:53:59Z"],"dc:date.issued":["2009"],"dc:description":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2009.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 66-68)."],"dc:description.abstract":["Experimental studies were performed to evaluate the kinetics and equilibrium binding constants of biomolecules in nanofluidic channels. Binding events in the nanochannel were detected using electrical and fluorescence methods. We concluded that antibody-antigen binding constants in nanochannels were similar to experiments performed in microtiter plates at low antigen concentrations; however the bound fraction in nanochannels at high antigen concentration decreased due to steric hindrance. Binding kinetics in nanochannels was limited by convective transport of analytes, instead of diffusion or reaction. We also found that enzymatic reactions in nanochannels were very effective due to short diffusion length and high surface area to volume ratio. A bead based ELISA was developed to exploit the rapid binding reactions in the bulk and efficient enzymatic conversion in the nanochannels. Additionally, electrokinetic concentrators were integrated with multiplexed bead based ELISA to further improve the detection sensitivity of a sandwich immunoassay."],"dc:description.degree":["S.M."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/55148"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["Development of an Enzyme-Linked ImmunoSorbent Assay (ELISA) with Enhanced Sensitivity in a Nanofluidic System"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:22:26Z"}