{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/54542"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/54542","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Inter-fingercoordinated DC motor driven grasping robotic hand","abstract":"Many robotic hands have individually driven joints, which is both energy inefficient and complicated to control. An alternative method includes employing only one motor to control multiple joints. Investigating humanoid hand movements used in everyday tasks, graduate students working with Professor Asada discovered through Principal Component Analysis that a majority of these motions can be approximated by a grasping motion. Implementing PCA results on a humanoid robotic hand yields an inter-finger coordinated motion in which each of the four fingers closes towards the palm and each individual joint's velocity is linearly proportional to the others. The coordination is achieved through a system of pulleys with different radii. The cables used in conjunction with these pulleys, emulating tendons, will be driven by a DC motor for simple control of a complex hand mechanism. The thumb is excluded from this system as it functions differently from the remaining digits.","abstract_html":"Many robotic hands have individually driven joints, which is both energy inefficient and complicated to control. An alternative method includes employing only one motor to control multiple joints. Investigating humanoid hand movements used in everyday tasks, graduate students working with Professor Asada discovered through Principal Component Analysis that a majority of these motions can be approximated by a grasping motion. Implementing PCA results on a humanoid robotic hand yields an inter-finger coordinated motion in which each of the four fingers closes towards the palm and each individual joint&#x27;s velocity is linearly proportional to the others. The coordination is achieved through a system of pulleys with different radii. The cables used in conjunction with these pulleys, emulating tendons, will be driven by a DC motor for simple control of a complex hand mechanism. The thumb is excluded from this system as it functions differently from the remaining digits.","abstract_has_math":false,"creators":["Wikman, Sarah Jane"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["H. Harry Asada."],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009","date_published":"2009","updated_at":"2026-07-22T22:21:45Z","subjects":["Mechanical Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/54542","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["H. Harry Asada."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Wikman, Sarah Jane"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-04-28T16:58:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-04-28T16:58:50Z"]},{"key":"dc:date.issued","label":"Date","values":["2009"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/54542"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2009.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 16)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Many robotic hands have individually driven joints, which is both energy inefficient and complicated to control. An alternative method includes employing only one motor to control multiple joints. Investigating humanoid hand movements used in everyday tasks, graduate students working with Professor Asada discovered through Principal Component Analysis that a majority of these motions can be approximated by a grasping motion. Implementing PCA results on a humanoid robotic hand yields an inter-finger coordinated motion in which each of the four fingers closes towards the palm and each individual joint's velocity is linearly proportional to the others. The coordination is achieved through a system of pulleys with different radii. The cables used in conjunction with these pulleys, emulating tendons, will be driven by a DC motor for simple control of a complex hand mechanism. The thumb is excluded from this system as it functions differently from the remaining digits."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:title","label":"Title","values":["Inter-fingercoordinated DC motor driven grasping robotic hand"]}]}],"canonical_facts":{"dc:contributor.advisor":["H. Harry Asada."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Wikman, Sarah Jane"],"dc:date.accessioned":["2010-04-28T16:58:50Z"],"dc:date.available":["2010-04-28T16:58:50Z"],"dc:date.issued":["2009"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2009.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 16)."],"dc:description.abstract":["Many robotic hands have individually driven joints, which is both energy inefficient and complicated to control. An alternative method includes employing only one motor to control multiple joints. Investigating humanoid hand movements used in everyday tasks, graduate students working with Professor Asada discovered through Principal Component Analysis that a majority of these motions can be approximated by a grasping motion. Implementing PCA results on a humanoid robotic hand yields an inter-finger coordinated motion in which each of the four fingers closes towards the palm and each individual joint's velocity is linearly proportional to the others. The coordination is achieved through a system of pulleys with different radii. The cables used in conjunction with these pulleys, emulating tendons, will be driven by a DC motor for simple control of a complex hand mechanism. The thumb is excluded from this system as it functions differently from the remaining digits."],"dc:description.degree":["S.B."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/54542"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Inter-fingercoordinated DC motor driven grasping robotic hand"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:45Z"}