Back to results

Massachusetts Institute of Technology

Evaluating the biostability of polypyrrole microwires

Abstract

dc:description.abstract

The ability to record signals from the brain has wide reaching applications in medicine and the study of the brain. Currently long term neural recording is precluded by the formation of scar tissue around the electrodes inserted into the brain. Conducting polymers present a possible solution to this problem as their biocompatibility and low stiffness could improve the quality of the interface between the electrode and the brain. In order to assess the long term stability of conducting polymers, electrodes are fabricated from polypyrrole using a variety of dopants to improve conductivity. These electrodes are then immersed in artificial cerebrospinal fluid while impedance measurements are taken over a period of days. The impedance of the electrodes increases rapidly for the first 40 hours before leveling off with only a slow increase in impedance being observed over the next 80 hours. When the ends of the electrodes are trimmed the impedance drops and then undergoes an accelerated rise and levels off. An experiment on the dimensional changes of the polypyrrole reveals that the polymer shrinks when placed into the solution. This may affect the integrity of the electrode and contribute to the increasing impedance. Further research will be necessary to understand the mechanism of the impedance increase and the electromechanical behavior of polymers with different biocompatible dopants.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wendell, Ross J. (Ross Joseph)
Advisor dc:contributor.advisor
  • Ian W. Hunter.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/54541
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/54541

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Wendell, Ross J. (Ross Joseph). Evaluating the biostability of polypyrrole microwires. Massachusetts Institute of Technology, 2009. http://hdl.handle.net/1721.1/54541