Back to results

Massachusetts Institute of Technology

Systematic characterization and calibration of a three dimensional ultrasonic positioning system for use in mobile robots

Abstract

dc:description.abstract

This thesis examined the characteristics of the Hexamite Hx11 ultrasonic sensor for the purpose of three dimensional positioning for mobile robots with multi-plane motions. The sensor system was studied and an experiment was conducted to locate a still transponder in the air using three transmitters on the ground. Due to the angular range of the transponder and the transmitters, data were not logged all of the time. An approximate lower z limit boundary surface was calculated, which predicted the behavior of 70% of the tests in the experiment. Sporadic errors were present in some of the data, with no apparent relation to the geometry of the experiment. If the erroneous parts were to be excluded, the accuracy and precision of the data obtained seemed to be quite high. It is concluded that further researches still needed to be done to determine the sources of the sporadic errors that appeared in some the data, and as of date, the Hexamite Hx11 ultrasonic positioning system cannot be reliably used for three dimensional sensing.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wu, Yi Fei, S. B. Massachusetts Institute of Technology
Advisor dc:contributor.advisor
  • Franz S. Hover.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/54538
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/54538

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Wu, Yi Fei, S. B. Massachusetts Institute of Technology. Systematic characterization and calibration of a three dimensional ultrasonic positioning system for use in mobile robots. Massachusetts Institute of Technology, 2009. http://hdl.handle.net/1721.1/54538