A numerical analysis of condenser performance of a seawater desalination system

Abstract

dc:description.abstract

This thesis presents the numerical analysis of three type condensers for desalination of seawater system. The condensers that were analyzed were a finned tube condenser that was built in Malaysia desalination plant, a cooling tube condenser in Jordan, and a common plate finned tube condenser. The goal of the analysis is to observe the thermal performance parameters of a condenser such as heat and mass transfer coefficient, surface effectiveness and condensate flow rate. The parameters that were changed in the analysis were the face velocity of air, the water velocity, and the number of rows of tubes. The numerical analysis was done based on basic heat exchanger analysis using e-NTU method for a dry case, and using a j-factor correlation that was developed by McQuiston for studying the wet case. Results from the basic heat exchanger analysis showed the air humidity ratio profile and temperature profile of air and water at the outlet of the condenser. The exit air temperature and humidity ratio were inversely proportional to the length of the condenser, whereas the temperature of the water at the outlet was proportional to the length of the condenser. Results from the j-factor correlation method show that the heat and mass transfer coefficient of the system increased when the number of rows of tubes, face velocity and water velocity increased. Similarly, the analysis showed that the condensate flow rate was highly influenced by the face velocity. In addition, the surface effectiveness was inversely proportional to the face velocity.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mohamed, Hassan, S.B. Massachusetts Institute of Technology
Advisor dc:contributor.advisor
  • John H. Lienhard, V.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/54517
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/54517

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Mohamed, Hassan, S.B. Massachusetts Institute of Technology. A numerical analysis of condenser performance of a seawater desalination system. Massachusetts Institute of Technology, 2009. http://hdl.handle.net/1721.1/54517