Back to results

Massachusetts Institute of Technology

Cardiac output estimation from arterial blood pressure waveforms using the MIMIC II database

Abstract

dc:description.abstract

The effect of signal quality on the accuracy of cardiac output (CO) estimation from arterial blood pressure (ABP) was evaluated using data from the Multi-Parameter Intelligent Patient Monitoring for Intensive Care (MIMIC) II database. Thermodilution CO (TCO) was the gold standard, and a total of 121 records with 1,497 TCO measurements were used. Six lumped-parameter and systolic area CO estimators were tested, using ABP features and a robust heart rate (HR) estimate. Signal quality indices for ABP and HR were calculated using previously described metrics. For retrospective analysis, results showed that the Liljestrand estimator yielded the lowest error for all levels of signal quality and for any single estimator when using five or more calibration points. Increasing signal quality decreased error and only marginally reduced the amount of available data, as a signal quality level of 90% preserved sufficient data for almost continuous CO estimation. At the recommended signal quality thresholds, the lowest gross root mean square normalized error (RMSNE) was found to be 15.4% (or 0.74 L/min) and average RMSNE was 13.7% (0.71 L/min). Based on these results, a linear combination (LC) of the six CO estimation methods was developed and proved superior to all other methods when up to 13 TCO calibration values were used. The clinical utility of the CO estimates were examined by correlating changes in four vasoactive medication doses with corresponding changes in estimated resistance, which was derived from mean ABP and estimated CO.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Chen, Tiffany
Advisor dc:contributor.advisor
  • Roger G. Mark.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/53096
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/53096

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Chen, Tiffany. Cardiac output estimation from arterial blood pressure waveforms using the MIMIC II database. Massachusetts Institute of Technology, 2009. http://hdl.handle.net/1721.1/53096