{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/51605"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/51605","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"First limit from a surface run of a 10 liter Dark Matter Time Projection Chamber","abstract":"A 10 liter prototype Dark Matter Time Projection Chamber (DMTPC) is operated on the surface of the earth at 75 Torr using carbon-tetrafluoride (CF4) as a target material to obtain a 24.57 gram-day exposure. A limit is set on a likely dark matter candidate, the weakly interacting massive particle. This is the first limit from the DMTPC detector, and the goal is to understand the sensitivity of the detector. In addition, this detector is used to measure the mean energy and attenuation coefficient of electrons propagating in CF4.","abstract_html":"A 10 liter prototype Dark Matter Time Projection Chamber (DMTPC) is operated on the surface of the earth at 75 Torr using carbon-tetrafluoride (CF4) as a target material to obtain a 24.57 gram-day exposure. A limit is set on a likely dark matter candidate, the weakly interacting massive particle. This is the first limit from the DMTPC detector, and the goal is to understand the sensitivity of the detector. In addition, this detector is used to measure the mean energy and attenuation coefficient of electrons propagating in CF4.","abstract_has_math":false,"creators":["Caldwell, Thomas S., Jr"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Physics.","school":null,"contributors":[],"advisors":["Peter Fisher."],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009","date_published":"2009","updated_at":"2026-07-22T22:22:13Z","subjects":["Physics."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/51605","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Peter Fisher."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Physics."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Physics."]},{"key":"dc:creator","label":"Author","values":["Caldwell, Thomas S., Jr"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-02-09T16:50:21Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-02-09T16:50:21Z"]},{"key":"dc:date.issued","label":"Date","values":["2009"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/51605"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Physics, 2009.","Includes bibliographical references (leaves 35-37)."]},{"key":"dc:description.abstract","label":"Abstract","values":["A 10 liter prototype Dark Matter Time Projection Chamber (DMTPC) is operated on the surface of the earth at 75 Torr using carbon-tetrafluoride (CF4) as a target material to obtain a 24.57 gram-day exposure. A limit is set on a likely dark matter candidate, the weakly interacting massive particle. This is the first limit from the DMTPC detector, and the goal is to understand the sensitivity of the detector. In addition, this detector is used to measure the mean energy and attenuation coefficient of electrons propagating in CF4."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:title","label":"Title","values":["First limit from a surface run of a 10 liter Dark Matter Time Projection Chamber"]}]}],"canonical_facts":{"dc:contributor.advisor":["Peter Fisher."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Physics."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Physics."],"dc:creator":["Caldwell, Thomas S., Jr"],"dc:date.accessioned":["2010-02-09T16:50:21Z"],"dc:date.available":["2010-02-09T16:50:21Z"],"dc:date.issued":["2009"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Physics, 2009.","Includes bibliographical references (leaves 35-37)."],"dc:description.abstract":["A 10 liter prototype Dark Matter Time Projection Chamber (DMTPC) is operated on the surface of the earth at 75 Torr using carbon-tetrafluoride (CF4) as a target material to obtain a 24.57 gram-day exposure. A limit is set on a likely dark matter candidate, the weakly interacting massive particle. This is the first limit from the DMTPC detector, and the goal is to understand the sensitivity of the detector. In addition, this detector is used to measure the mean energy and attenuation coefficient of electrons propagating in CF4."],"dc:description.degree":["S.B."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/51605"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Physics."],"dc:title":["First limit from a surface run of a 10 liter Dark Matter Time Projection Chamber"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:22:13Z"}