Back to results

Massachusetts Institute of Technology

Accelerator-Based Neutron Branchytherapy

Abstract

dc:description.abstract

The feasibility of a new modality of radiation therapy, Accelerator-Based Neutron Brachytherapy (ABNBT), has been demonstrated through simulations and experimental work. The candidate nuclear reactions investigated are 9Be(d,n)'OB, 9Be(p,n)9B, and 7Li(p,n)7Be, with charged particle beam energies of less than 4.1 MeV. The focus of this work is the treatment of intracranial tumors which limits the diameter of the dose delivery needle tube to 6 mm. A prototype needle tube, a tube-in-tube design with cooling water running in between the inner and outer tubes to cool the beryllium target located at the tip of the inner tube, has been tested to a heat load near 150 Watts. The insertion length is 10 cm. The dosimetric characteristics were simulated using the Monte Carlo code MCNP and the treatment times were then calculated for a given heat load. The simulations and calculations show that the fast neutron dose is the dominant dose component for all the candidate reactions. The 9Be(d,n)oB reaction at Ed=1.5 MeV is capable of delivering a therapeutic dose of 66 RBE.Gy to the boundary of a 4.5 cm diameter tumor in 7.3 minutes at a heat load of 150 Watts. The other two candidate reactions deliver a similar dose rate at the same heat load to the target at a beam energy near 4.0 MeV. However, they show higher potential for dose enhancement with the boron-10 neutron capture reaction due to their soft neutron spectra. For input into dosimetric simulations, the source gammas from a thick beryllium target bombarded by a 1.5 MeV deuteron beam were measured at 600 with a 76 mm x 76 mm NaI(TI) detector. The prominent gammas range from 414 keV to 3.6 MeV. Dose distributions in a water phantom were measured with the prototype needle tube using the dual-ion chamber technique for the 9Be(d,n)10B reaction at Ed=1.5 MeV. The measurements and simulations agree within uncertainties. In conclusion this work has demonstrated the dosimetric desirability and the practical feasibility of ABNBT for the treatment of interstitial or intracavity tumors.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Physics
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
1998

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Song, Haijun, 1970-
Advisor dc:contributor.advisor
  • Jacquelyn C. Yanch and Lee Grodzins.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/50501
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/50501

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Song, Haijun, 1970-. Accelerator-Based Neutron Branchytherapy. Massachusetts Institute of Technology, 1998. http://hdl.handle.net/1721.1/50501