Back to results

Massachusetts Institute of Technology

Coil performance evaluation based on electrodynamics : tools for hardware design and validation in magnetic resonance imaging

Abstract

dc:description.abstract

Parallel MRI techniques allow acceleration of MR imaging beyond traditional speed limits. In parallel MRI, radiofrequency (RF) detector coil arrays are used to perform some degree of spatial encoding which complements traditional encoding using magnetic field gradients. As the acceleration factor increases, coil design becomes critical to the overall image quality. The quality of a design is commonly judged on how it compares with other coil configurations. A procedure to evaluate the absolute performance of RF coil arrays is proposed. Electromagnetic calculations to compute the ultimate intrinsic signal-to-noise ratio (SNR) available for any physically realizable coil array are shown, and coil performance maps are generated based on the ratio of experimentally measured SNR to this ultimate intrinsic SNR. Parallel excitation, which involves independent transmission with multiple RF coils distributed around the body, can be used to improve the homogeneity of RF excitations and minimize the RF energy deposited in tissues - both critical issues for MRI at high magnetic field strength. As its use is explored further, it will be important to investigate the intrinsic constraints of the technique. We studied the trade-off between transmit homogeneity and specific absorption rate (SAR) reduction with respect to main magnetic field strength, object size and acceleration. We introduced the concept of ultimate intrinsic SAR, the theoretical smallest RF energy deposition for a target flip angle distribution, and we calculated the corresponding ideal current patterns. Knowledge of these optimal current patterns will serve as an important guide for future high-field coil designs.

Degree

thesis:*
Department dc:contributor.department
Harvard University--MIT Division of Health Sciences and Technology
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2008

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lattanzi, Riccardo
Advisor dc:contributor.advisor
  • Daniel K. Sodickson.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/45909
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/45909

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Lattanzi, Riccardo. Coil performance evaluation based on electrodynamics : tools for hardware design and validation in magnetic resonance imaging. Massachusetts Institute of Technology, 2008. http://hdl.handle.net/1721.1/45909