{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/45857"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/45857","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Electromyographic control of prosthetic voice after total laryngectomy","abstract":"The electrolarynx (EL) is a common rehabilitative speech aid for individuals who have undergone laryngectomy, but typical devices lack pitch control and require the exclusive use of one hand. This study investigated the viability of surface electromyography (sEMG) to control the onset and offset of an EMG-controlled EL (EMG-EL) while attending to real-time sEMG biofeedback using sEMG collected from seven locations across the ventral neck and face surface in eight individuals at least 1 year past total laryngectomy.Speech performance was assessed as the percentage of fully voiced words and successfully produced pauses. During use of the EMG-EL with biofeedback participants increased the sEMG during words and decreased the sEMG during pauses. Electrodes on the superior ventral neck, submental surface, and below the comer of the mouth showed consistently high performance across all participants. These results indicate promise for the applicability of the EMG-EL across a large segment of the laryngectomy population.","abstract_html":"The electrolarynx (EL) is a common rehabilitative speech aid for individuals who have undergone laryngectomy, but typical devices lack pitch control and require the exclusive use of one hand. This study investigated the viability of surface electromyography (sEMG) to control the onset and offset of an EMG-controlled EL (EMG-EL) while attending to real-time sEMG biofeedback using sEMG collected from seven locations across the ventral neck and face surface in eight individuals at least 1 year past total laryngectomy.Speech performance was assessed as the percentage of fully voiced words and successfully produced pauses. During use of the EMG-EL with biofeedback participants increased the sEMG during words and decreased the sEMG during pauses. Electrodes on the superior ventral neck, submental surface, and below the comer of the mouth showed consistently high performance across all participants. These results indicate promise for the applicability of the EMG-EL across a large segment of the laryngectomy population.","abstract_has_math":false,"creators":["Stepp, Cara Elizabeth"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.","school":null,"contributors":[],"advisors":["Joseph S. Perkell and James T. Heaton."],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008","date_published":"2008","updated_at":"2026-07-22T22:22:04Z","subjects":["Electrical Engineering and Computer Science."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/45857","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Joseph S. Perkell and James T. Heaton."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Stepp, Cara Elizabeth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-06-30T16:26:36Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-06-30T16:26:36Z"]},{"key":"dc:date.issued","label":"Date","values":["2008"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/45857"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2008.","Includes bibliographical references (p. 41-43)."]},{"key":"dc:description.abstract","label":"Abstract","values":["The electrolarynx (EL) is a common rehabilitative speech aid for individuals who have undergone laryngectomy, but typical devices lack pitch control and require the exclusive use of one hand. This study investigated the viability of surface electromyography (sEMG) to control the onset and offset of an EMG-controlled EL (EMG-EL) while attending to real-time sEMG biofeedback using sEMG collected from seven locations across the ventral neck and face surface in eight individuals at least 1 year past total laryngectomy.Speech performance was assessed as the percentage of fully voiced words and successfully produced pauses. During use of the EMG-EL with biofeedback participants increased the sEMG during words and decreased the sEMG during pauses. Electrodes on the superior ventral neck, submental surface, and below the comer of the mouth showed consistently high performance across all participants. These results indicate promise for the applicability of the EMG-EL across a large segment of the laryngectomy population."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:title","label":"Title","values":["Electromyographic control of prosthetic voice after total laryngectomy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Joseph S. Perkell and James T. Heaton."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."],"dc:creator":["Stepp, Cara Elizabeth"],"dc:date.accessioned":["2009-06-30T16:26:36Z"],"dc:date.available":["2009-06-30T16:26:36Z"],"dc:date.issued":["2008"],"dc:description":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2008.","Includes bibliographical references (p. 41-43)."],"dc:description.abstract":["The electrolarynx (EL) is a common rehabilitative speech aid for individuals who have undergone laryngectomy, but typical devices lack pitch control and require the exclusive use of one hand. This study investigated the viability of surface electromyography (sEMG) to control the onset and offset of an EMG-controlled EL (EMG-EL) while attending to real-time sEMG biofeedback using sEMG collected from seven locations across the ventral neck and face surface in eight individuals at least 1 year past total laryngectomy.Speech performance was assessed as the percentage of fully voiced words and successfully produced pauses. During use of the EMG-EL with biofeedback participants increased the sEMG during words and decreased the sEMG during pauses. Electrodes on the superior ventral neck, submental surface, and below the comer of the mouth showed consistently high performance across all participants. These results indicate promise for the applicability of the EMG-EL across a large segment of the laryngectomy population."],"dc:description.degree":["S.M."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/45857"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["Electromyographic control of prosthetic voice after total laryngectomy"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:22:04Z"}