Design and fabrication of a precision alignment system and package for a two-photon fluorescence imaging device

Abstract

dc:description.abstract

A compact, lightweight precision alignment system and package for an endomicroscope was designed and fabricated. The endomicroscope will consist of a millimeter-scale fiber resonator and a two-axis silicon optical bench. The alignment system provided five degrees of freedom and was designed to align the fiber resonator with the microchip with a resolution of one micron. The alignment system consisted of a system of ultra-fine screws and two compliant mechanisms to deamplify the motion of the screw. Finite element analysis was performed to optimize the compliant mechanisms for the desired transmission ratio of 20:1. The alignment system was fabricated and testing showed that the transmission ratios were lower than expected (18.6 for one compliant mechanism and 2.68 for the other). Testing also showed that the alignment system met the functional requirements for the ranges of motion.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2008

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Chang, Jean H
Advisor dc:contributor.advisor
  • Martin L. Culpepper.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/45776
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/45776

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Chang, Jean H. Design and fabrication of a precision alignment system and package for a two-photon fluorescence imaging device. Massachusetts Institute of Technology, 2008. http://hdl.handle.net/1721.1/45776