{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/45766"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/45766","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Characterization and testing of a height adjustable kinematic coupling","abstract":"A new height adjustable kinematic coupling has been designed for a next generation high precision ceramics grinding machine designed to have total loop stiffness of 60 N/[mu]m. A test apparatus and prototype of the new coupling design has been built as the subject of this thesis to test the coupling in a model of the grinding machine layout to characterize coupling stiffness and range & precision of height adjustability. Here, the prototype coupling and test apparatus design, with initial results that verify the system's manufacturing are reported. Some design revisions to the coupling are also suggested. Future work will report coupling characterization and coupling-machine integration. Other future work will use this test setup to test and optimize control system design of the three- groove active kinematic coupling layout and finalize the component choice for the production grinding machine.","abstract_html":"A new height adjustable kinematic coupling has been designed for a next generation high precision ceramics grinding machine designed to have total loop stiffness of 60 N/[mu]m. A test apparatus and prototype of the new coupling design has been built as the subject of this thesis to test the coupling in a model of the grinding machine layout to characterize coupling stiffness and range &amp; precision of height adjustability. Here, the prototype coupling and test apparatus design, with initial results that verify the system&#x27;s manufacturing are reported. Some design revisions to the coupling are also suggested. Future work will report coupling characterization and coupling-machine integration. Other future work will use this test setup to test and optimize control system design of the three- groove active kinematic coupling layout and finalize the component choice for the production grinding machine.","abstract_has_math":false,"creators":["Bosworth, William R., Ph. D. Massachusetts Institute of Technology"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Alexander H. Slocum."],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008","date_published":"2008","updated_at":"2026-07-22T22:22:30Z","subjects":["Mechanical Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/45766","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Alexander H. Slocum."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Bosworth, William R., Ph. D. Massachusetts Institute of Technology"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-06-30T16:14:31Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-06-30T16:14:31Z"]},{"key":"dc:date.issued","label":"Date","values":["2008"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/45766"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2008.","Includes bibliographical references (p. 21-22)."]},{"key":"dc:description.abstract","label":"Abstract","values":["A new height adjustable kinematic coupling has been designed for a next generation high precision ceramics grinding machine designed to have total loop stiffness of 60 N/[mu]m. A test apparatus and prototype of the new coupling design has been built as the subject of this thesis to test the coupling in a model of the grinding machine layout to characterize coupling stiffness and range & precision of height adjustability. Here, the prototype coupling and test apparatus design, with initial results that verify the system's manufacturing are reported. Some design revisions to the coupling are also suggested. Future work will report coupling characterization and coupling-machine integration. Other future work will use this test setup to test and optimize control system design of the three- groove active kinematic coupling layout and finalize the component choice for the production grinding machine."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:title","label":"Title","values":["Characterization and testing of a height adjustable kinematic coupling"]}]}],"canonical_facts":{"dc:contributor.advisor":["Alexander H. Slocum."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Bosworth, William R., Ph. D. Massachusetts Institute of Technology"],"dc:date.accessioned":["2009-06-30T16:14:31Z"],"dc:date.available":["2009-06-30T16:14:31Z"],"dc:date.issued":["2008"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2008.","Includes bibliographical references (p. 21-22)."],"dc:description.abstract":["A new height adjustable kinematic coupling has been designed for a next generation high precision ceramics grinding machine designed to have total loop stiffness of 60 N/[mu]m. A test apparatus and prototype of the new coupling design has been built as the subject of this thesis to test the coupling in a model of the grinding machine layout to characterize coupling stiffness and range & precision of height adjustability. Here, the prototype coupling and test apparatus design, with initial results that verify the system's manufacturing are reported. Some design revisions to the coupling are also suggested. Future work will report coupling characterization and coupling-machine integration. Other future work will use this test setup to test and optimize control system design of the three- groove active kinematic coupling layout and finalize the component choice for the production grinding machine."],"dc:description.degree":["S.B."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/45766"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Characterization and testing of a height adjustable kinematic coupling"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:22:30Z"}