Back to results

Massachusetts Institute of Technology

Evaluating energy dissipation during expansion in a refrigeration cycle using flue pipe acoustic resonators

Abstract

dc:description.abstract

This research evaluates the feasibility of using a flue pipe acoustic resonator to dissipate energy from a refrigerant stream in order to achieve greater cooling power from a cryorefrigeration cycle. Two models of the acoustic operation of flue pipe resonant systems are examined: an electrical circuit analog that represents the linear approximation of the acoustic system and a numerical model based on empirical data. The electrical analog yields a symbolic representation for the power that can potentially be dissipated from the acoustic stream. Ongoing research into these acoustic systems, however, shows that the electrical analog, which neglects nonlinear effects, is incomplete and overestimates the operation of a pipe. However, the analogy can be used to quickly find the order of magnitude of power dissipated from the acoustic resonator. A subsequent data-based model allows for a more accurate quantitative estimation of the potential efficiency of the flue pipe in extracting work and thereby dissipating energy from a refrigerant stream. The efficiency of extracting work from a refrigerant stream using the acoustic system analyzed here ranges from 10% to 60%. The range is so large because the quality factor of the experimental flue pipe is unknown. This quality factor is imperative in determining the power dissipation. Further research should optimize the quality factor. A large quality factor causes less amplitude attenuation than a small one, but a smaller one dissipates more of the stored energy. The results of the models are compared to the efficiencies of existing technology, specifically the recently invented thermo acoustic expansion valve (TEV). It is found that the efficiency of the TEV is less than the theoretical results deduced from the numerical model. At an efficiency of approximately 10%, the technology represents a gain in cooling power, but further optimization using the results of this research can increase this gain even more.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2008

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Luckyanova, Maria N. (Maria Nickolayevna)
Advisor dc:contributor.advisor
  • John G. Brisson.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/45328
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/45328

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Luckyanova, Maria N. (Maria Nickolayevna). Evaluating energy dissipation during expansion in a refrigeration cycle using flue pipe acoustic resonators. Massachusetts Institute of Technology, 2008. http://hdl.handle.net/1721.1/45328