Back to results

Massachusetts Institute of Technology

Evaluation of spatial-spectral filtering in non-paraxial volume holographic imaging systems

Abstract

dc:description.abstract

In this thesis, the properties of transmission-mode volume phase holograms as spatial-spectral filters in optical systems for microscopic medical imaging are evaluated. In experiment, the relationship between the angle of incidence and diffraction efficiency are invesitgated for wavelength-detuned multiplex holograms to establish the limits of the narrow bandwidth lateral field of view. The depth selectivity of the microscope with a volume hologram pupil is also measured and found to vary significantly with recording parameters and lateral shift of the probe point source in object space. This experiment is modified to incorporate controlled levels of spherical aberration, where the effect on the depth selectivity is evaluated. A novel resolution target designed specifically for the evaluation of this imaging system is described and imaged. A flexible approach based on the 1st-order Born approximation is implemented to simulate all aspects of the imaging system with a multiplex volume hologram pupil. The simulation is then used to verify and expand upon the experimental results. A mathematical treatment of the nature of the anomalous apparent curvature of the diffraction image is performed, showing that a volume grating recorded in plane has weak out-of-plane spatial filtering behavior.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2008

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Watson, Jonathan M
Advisor dc:contributor.advisor
  • George Barbastathis.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/44854
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/44854

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Watson, Jonathan M. Evaluation of spatial-spectral filtering in non-paraxial volume holographic imaging systems. Massachusetts Institute of Technology, 2008. http://hdl.handle.net/1721.1/44854