{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/44837"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/44837","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Long range x-ray imaging utilizing coded aperture techniques and dynamic reconstruction","abstract":"Improvised explosive devices (IED) pose a very serious threat to civilians and military forces around the world, and new technologies must be developed for the early detection of these objects. Because of the high concentrations of low atomic number material such as nitrogen and hydrogen present in these explosives, x-ray backscattering provides a viable method of collecting information about these targets by analyzing their shape. Furthermore, a coded aperture used in conjunction with dynamic reconstruction algorithms offers high sensitivity and resolution even while the target is moving towards the detector. This paper describes a lab-based system that simulated a source-target-detector arrangement to be utilized in a radiation detecting vehicle in order to test dynamic reconstruction methods. Using a 225 kVp x-ray tube as the source, a medical CT-system camera fitted with a drill mask of 50% fill factor as the detector, and both radioisotope sources and low Z backscatter targets, images were acquired and reconstructed. The geometry of the experimental setup was optimized to reduce background noise from air scatter and environmental sources, as well as to prevent incident photons from directly reaching the detector from the x-ray tube. Measurements of a Co-60 point source and Co-57 area source with high activity generated high contrast images for which the shapes of the sources were clearly resolved. Acquisitions with varying target-detector distance of low Z materials, including a filled water jug and a four inch thick polyethylene arrow, produced lower contrast images in which the shapes were not as easily distinguished. The radioisotope tests were a proof of principle for dynamic reconstruction and the backscatter targets provided much insight on methods for improving the lab system, including the addition of steel behind the target, the narrowing of the detector energy window, and reassessment of the x-ray cone-beam.","abstract_html":"Improvised explosive devices (IED) pose a very serious threat to civilians and military forces around the world, and new technologies must be developed for the early detection of these objects. Because of the high concentrations of low atomic number material such as nitrogen and hydrogen present in these explosives, x-ray backscattering provides a viable method of collecting information about these targets by analyzing their shape. Furthermore, a coded aperture used in conjunction with dynamic reconstruction algorithms offers high sensitivity and resolution even while the target is moving towards the detector. This paper describes a lab-based system that simulated a source-target-detector arrangement to be utilized in a radiation detecting vehicle in order to test dynamic reconstruction methods. Using a 225 kVp x-ray tube as the source, a medical CT-system camera fitted with a drill mask of 50% fill factor as the detector, and both radioisotope sources and low Z backscatter targets, images were acquired and reconstructed. The geometry of the experimental setup was optimized to reduce background noise from air scatter and environmental sources, as well as to prevent incident photons from directly reaching the detector from the x-ray tube. Measurements of a Co-60 point source and Co-57 area source with high activity generated high contrast images for which the shapes of the sources were clearly resolved. Acquisitions with varying target-detector distance of low Z materials, including a filled water jug and a four inch thick polyethylene arrow, produced lower contrast images in which the shapes were not as easily distinguished. The radioisotope tests were a proof of principle for dynamic reconstruction and the backscatter targets provided much insight on methods for improving the lab system, including the addition of steel behind the target, the narrowing of the detector energy window, and reassessment of the x-ray cone-beam.","abstract_has_math":false,"creators":["Lee, Tiffany (Tiffany Ting)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Nuclear Science and Engineering.","school":null,"contributors":[],"advisors":["Richard C. Lanza."],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008","date_published":"2008","updated_at":"2026-07-22T22:21:11Z","subjects":["Nuclear Science and Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/44837","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Richard C. Lanza."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Nuclear Science and Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Nuclear Science and Engineering."]},{"key":"dc:creator","label":"Author","values":["Lee, Tiffany (Tiffany Ting)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-03-16T19:49:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-03-16T19:49:18Z"]},{"key":"dc:date.issued","label":"Date","values":["2008"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Nuclear Science and Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/44837"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, 2008.","Includes bibliographical references (p. 50)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Improvised explosive devices (IED) pose a very serious threat to civilians and military forces around the world, and new technologies must be developed for the early detection of these objects. Because of the high concentrations of low atomic number material such as nitrogen and hydrogen present in these explosives, x-ray backscattering provides a viable method of collecting information about these targets by analyzing their shape. Furthermore, a coded aperture used in conjunction with dynamic reconstruction algorithms offers high sensitivity and resolution even while the target is moving towards the detector. This paper describes a lab-based system that simulated a source-target-detector arrangement to be utilized in a radiation detecting vehicle in order to test dynamic reconstruction methods. Using a 225 kVp x-ray tube as the source, a medical CT-system camera fitted with a drill mask of 50% fill factor as the detector, and both radioisotope sources and low Z backscatter targets, images were acquired and reconstructed. The geometry of the experimental setup was optimized to reduce background noise from air scatter and environmental sources, as well as to prevent incident photons from directly reaching the detector from the x-ray tube. Measurements of a Co-60 point source and Co-57 area source with high activity generated high contrast images for which the shapes of the sources were clearly resolved. Acquisitions with varying target-detector distance of low Z materials, including a filled water jug and a four inch thick polyethylene arrow, produced lower contrast images in which the shapes were not as easily distinguished. The radioisotope tests were a proof of principle for dynamic reconstruction and the backscatter targets provided much insight on methods for improving the lab system, including the addition of steel behind the target, the narrowing of the detector energy window, and reassessment of the x-ray cone-beam."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:title","label":"Title","values":["Long range x-ray imaging utilizing coded aperture techniques and dynamic reconstruction"]}]}],"canonical_facts":{"dc:contributor.advisor":["Richard C. Lanza."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Nuclear Science and Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Nuclear Science and Engineering."],"dc:creator":["Lee, Tiffany (Tiffany Ting)"],"dc:date.accessioned":["2009-03-16T19:49:18Z"],"dc:date.available":["2009-03-16T19:49:18Z"],"dc:date.issued":["2008"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, 2008.","Includes bibliographical references (p. 50)."],"dc:description.abstract":["Improvised explosive devices (IED) pose a very serious threat to civilians and military forces around the world, and new technologies must be developed for the early detection of these objects. Because of the high concentrations of low atomic number material such as nitrogen and hydrogen present in these explosives, x-ray backscattering provides a viable method of collecting information about these targets by analyzing their shape. Furthermore, a coded aperture used in conjunction with dynamic reconstruction algorithms offers high sensitivity and resolution even while the target is moving towards the detector. This paper describes a lab-based system that simulated a source-target-detector arrangement to be utilized in a radiation detecting vehicle in order to test dynamic reconstruction methods. Using a 225 kVp x-ray tube as the source, a medical CT-system camera fitted with a drill mask of 50% fill factor as the detector, and both radioisotope sources and low Z backscatter targets, images were acquired and reconstructed. The geometry of the experimental setup was optimized to reduce background noise from air scatter and environmental sources, as well as to prevent incident photons from directly reaching the detector from the x-ray tube. Measurements of a Co-60 point source and Co-57 area source with high activity generated high contrast images for which the shapes of the sources were clearly resolved. Acquisitions with varying target-detector distance of low Z materials, including a filled water jug and a four inch thick polyethylene arrow, produced lower contrast images in which the shapes were not as easily distinguished. The radioisotope tests were a proof of principle for dynamic reconstruction and the backscatter targets provided much insight on methods for improving the lab system, including the addition of steel behind the target, the narrowing of the detector energy window, and reassessment of the x-ray cone-beam."],"dc:description.degree":["S.B."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/44837"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Nuclear Science and Engineering."],"dc:title":["Long range x-ray imaging utilizing coded aperture techniques and dynamic reconstruction"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:11Z"}