{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/44811"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/44811","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Synthesis of biodegradable hydrogel microparticles for vaccine protein delivery","abstract":"Soluble protein antigens used in vaccines have shown lower immune responses when compared with certain particulate forms of these same antigens. For example, it has been shown that micro- and nano-particle mediated delivery of protein antigen can use up to 100 times less protein and still produce an effective immune response [1]. In order to use this phenomenon to make vaccines more efficient, we need a biodegradable delivery particle. This thesis modifies a particle created by Jain et al., which consists of a polymer network surrounding and trapping a protein, by removing the non-degradable crosslinker used in the original particle design and replacing it with a poly (ethylene glycol) acrylate molecule attached to ovalbumin protein. When a dendritic cell degrades the particle, the ovalbumin protein will be degraded, as will the connections between the polymer network that holds the particle together [2]. The particles degraded to 56% of their original size in 3 days, while the non-degradable particle degraded to only 80% of its original size.","abstract_html":"Soluble protein antigens used in vaccines have shown lower immune responses when compared with certain particulate forms of these same antigens. For example, it has been shown that micro- and nano-particle mediated delivery of protein antigen can use up to 100 times less protein and still produce an effective immune response [1]. In order to use this phenomenon to make vaccines more efficient, we need a biodegradable delivery particle. This thesis modifies a particle created by Jain et al., which consists of a polymer network surrounding and trapping a protein, by removing the non-degradable crosslinker used in the original particle design and replacing it with a poly (ethylene glycol) acrylate molecule attached to ovalbumin protein. When a dendritic cell degrades the particle, the ovalbumin protein will be degraded, as will the connections between the polymer network that holds the particle together [2]. The particles degraded to 56% of their original size in 3 days, while the non-degradable particle degraded to only 80% of its original size.","abstract_has_math":false,"creators":["Werts, Kendall (Kendall Marie)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Materials Science and Engineering.","school":null,"contributors":[],"advisors":["Darrell Irvine."],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007","date_published":"2007","updated_at":"2026-07-22T22:21:35Z","subjects":["Materials Science and Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/44811","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Darrell Irvine."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Materials Science and Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Materials Science and Engineering."]},{"key":"dc:creator","label":"Author","values":["Werts, Kendall (Kendall Marie)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-03-16T19:46:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-03-16T19:46:37Z"]},{"key":"dc:date.issued","label":"Date","values":["2007"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Materials Science and Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/44811"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Materials Science and Engineering, 2007.","Includes bibliographical references (p. 21)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Soluble protein antigens used in vaccines have shown lower immune responses when compared with certain particulate forms of these same antigens. For example, it has been shown that micro- and nano-particle mediated delivery of protein antigen can use up to 100 times less protein and still produce an effective immune response [1]. In order to use this phenomenon to make vaccines more efficient, we need a biodegradable delivery particle. This thesis modifies a particle created by Jain et al., which consists of a polymer network surrounding and trapping a protein, by removing the non-degradable crosslinker used in the original particle design and replacing it with a poly (ethylene glycol) acrylate molecule attached to ovalbumin protein. When a dendritic cell degrades the particle, the ovalbumin protein will be degraded, as will the connections between the polymer network that holds the particle together [2]. The particles degraded to 56% of their original size in 3 days, while the non-degradable particle degraded to only 80% of its original size."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:title","label":"Title","values":["Synthesis of biodegradable hydrogel microparticles for vaccine protein delivery"]}]}],"canonical_facts":{"dc:contributor.advisor":["Darrell Irvine."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Materials Science and Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Materials Science and Engineering."],"dc:creator":["Werts, Kendall (Kendall Marie)"],"dc:date.accessioned":["2009-03-16T19:46:37Z"],"dc:date.available":["2009-03-16T19:46:37Z"],"dc:date.issued":["2007"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Materials Science and Engineering, 2007.","Includes bibliographical references (p. 21)."],"dc:description.abstract":["Soluble protein antigens used in vaccines have shown lower immune responses when compared with certain particulate forms of these same antigens. For example, it has been shown that micro- and nano-particle mediated delivery of protein antigen can use up to 100 times less protein and still produce an effective immune response [1]. In order to use this phenomenon to make vaccines more efficient, we need a biodegradable delivery particle. This thesis modifies a particle created by Jain et al., which consists of a polymer network surrounding and trapping a protein, by removing the non-degradable crosslinker used in the original particle design and replacing it with a poly (ethylene glycol) acrylate molecule attached to ovalbumin protein. When a dendritic cell degrades the particle, the ovalbumin protein will be degraded, as will the connections between the polymer network that holds the particle together [2]. The particles degraded to 56% of their original size in 3 days, while the non-degradable particle degraded to only 80% of its original size."],"dc:description.degree":["S.B."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/44811"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Materials Science and Engineering."],"dc:title":["Synthesis of biodegradable hydrogel microparticles for vaccine protein delivery"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:35Z"}