Back to results

Massachusetts Institute of Technology

Advanced brachytherapy dosimetric considerations

Abstract

dc:description.abstract

The practice of brachytherapy and brachytherapy dosimetry was investigated with emphasis on evaluations of dose distributions and shielding considerations for both photon- and neutron-emitting radionuclides. Monte Carlo simulation methods were employed to calculate dose distributions for virtual and commercial brachytherapy sources. Radionuclides studied were 103Pd, 1251, 131Cs, 137Cs, 169b, 192Ir, and 252Cf. 252Cf sources also emit neutrons from spontaneous fission. The brachytherapy dosimetry protocol recommended by the American Association of Physicists in Medicine was followed and evaluated for conditions of partial scatter (non-infinite media) and material inhomogeneities, both commonly encountered in brachytherapy treatment. Furthermore, energy-dependent characteristics of dosimetry parameters were evaluated and reference calculations performed for virtual photon and neutron sources. These findings were applied to three clinical brachytherapy cases: eye plaques using 103Pd, 125I, and 131Cs; high-dose rate 252Cf treatment; and, 2 Cf plaques for superficial lesions. For eye plaques, material heterogeneities were significant for each radionuclide with dose reduction at 5 mm of 18%, 11%, and 10% for P03pd, 125I, and 131Cs, respectively. For a proposed highdose rate 252Cf source (5mm length), relative brachytherapy dosimetry parameters were found to be similar to those obtained for a low-dose rate Applicator Tube-type source (15 mm length). Considering 252Cf plaque brachytherapy when partial scatter conditions were accounted for, central axis equivalent dose rate decreased by 11 ± 1% and 7 ± 2% for depths of 4 to 50 mm, respectively.

Degree

thesis:*
Department dc:contributor.department
Harvard University--MIT Division of Health Sciences and Technology.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2008

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Melhus, Christopher S. (Christopher Scott), 1974-
Advisor dc:contributor.advisor
  • Mark J. Rivard.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/43808
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/43808

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Melhus, Christopher S. (Christopher Scott), 1974-. Advanced brachytherapy dosimetric considerations. Massachusetts Institute of Technology, 2008. http://hdl.handle.net/1721.1/43808