{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/43017"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/43017","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Design, fabrication, and testing of a multichannel microfluidic device to dynamically control oxygen concentration conditions in-vitro","abstract":"Multilayer microfluidic devices were designed and fabricated such that an array of different oxygen concentrations could be applied to a testing area in any desired sequence and with unconstraint application times. The principle of flow resistance dictates that a large channel length will impose a larger resistance and therefore a larger reduction in flow rate versus a shorter channel length. To exploit this feature, the microfluidic device employs a fluidic resistance network composed of an array of predetermined variable length channels to generate different oxygen to nitrogen flow rate ratios, i.e. different oxygen concentrations. Standard lithographic techniques were used to fabricate the microfluidic devices, using highly gas permeable silicone rubber (polydimethylsiloxane (PDMS)). The stacked microchannel architecture, channel dimensions, and layer thicknesses in the device were optimized for rapid diffusion and saturation of 02 N2 mixtures into the testing areas. The oxygen concentration was dynamically monitored using polymeric fluorescence-based oxygen sensors integrated into the device. By altering oxygen levels over time, this device aims to selectively build up biofilms on the artificial tooth substrate as the process occurs in-vitro. A study concerning this application is also presented.","abstract_html":"Multilayer microfluidic devices were designed and fabricated such that an array of different oxygen concentrations could be applied to a testing area in any desired sequence and with unconstraint application times. The principle of flow resistance dictates that a large channel length will impose a larger resistance and therefore a larger reduction in flow rate versus a shorter channel length. To exploit this feature, the microfluidic device employs a fluidic resistance network composed of an array of predetermined variable length channels to generate different oxygen to nitrogen flow rate ratios, i.e. different oxygen concentrations. Standard lithographic techniques were used to fabricate the microfluidic devices, using highly gas permeable silicone rubber (polydimethylsiloxane (PDMS)). The stacked microchannel architecture, channel dimensions, and layer thicknesses in the device were optimized for rapid diffusion and saturation of 02 N2 mixtures into the testing areas. The oxygen concentration was dynamically monitored using polymeric fluorescence-based oxygen sensors integrated into the device. By altering oxygen levels over time, this device aims to selectively build up biofilms on the artificial tooth substrate as the process occurs in-vitro. A study concerning this application is also presented.","abstract_has_math":false,"creators":["Rodriguez, Rosa H"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Todd Thorsen."],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008","date_published":"2008","updated_at":"2026-07-22T22:21:39Z","subjects":["Mechanical Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/43017","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Todd Thorsen."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Rodriguez, Rosa H"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2008-11-07T18:52:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2008-11-07T18:52:29Z"]},{"key":"dc:date.issued","label":"Date","values":["2008"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/43017"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2008.","Includes bibliographical references (p. 63-64)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Multilayer microfluidic devices were designed and fabricated such that an array of different oxygen concentrations could be applied to a testing area in any desired sequence and with unconstraint application times. The principle of flow resistance dictates that a large channel length will impose a larger resistance and therefore a larger reduction in flow rate versus a shorter channel length. To exploit this feature, the microfluidic device employs a fluidic resistance network composed of an array of predetermined variable length channels to generate different oxygen to nitrogen flow rate ratios, i.e. different oxygen concentrations. Standard lithographic techniques were used to fabricate the microfluidic devices, using highly gas permeable silicone rubber (polydimethylsiloxane (PDMS)). The stacked microchannel architecture, channel dimensions, and layer thicknesses in the device were optimized for rapid diffusion and saturation of 02 N2 mixtures into the testing areas. The oxygen concentration was dynamically monitored using polymeric fluorescence-based oxygen sensors integrated into the device. By altering oxygen levels over time, this device aims to selectively build up biofilms on the artificial tooth substrate as the process occurs in-vitro. A study concerning this application is also presented."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:title","label":"Title","values":["Design, fabrication, and testing of a multichannel microfluidic device to dynamically control oxygen concentration conditions in-vitro"]}]}],"canonical_facts":{"dc:contributor.advisor":["Todd Thorsen."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Rodriguez, Rosa H"],"dc:date.accessioned":["2008-11-07T18:52:29Z"],"dc:date.available":["2008-11-07T18:52:29Z"],"dc:date.issued":["2008"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2008.","Includes bibliographical references (p. 63-64)."],"dc:description.abstract":["Multilayer microfluidic devices were designed and fabricated such that an array of different oxygen concentrations could be applied to a testing area in any desired sequence and with unconstraint application times. The principle of flow resistance dictates that a large channel length will impose a larger resistance and therefore a larger reduction in flow rate versus a shorter channel length. To exploit this feature, the microfluidic device employs a fluidic resistance network composed of an array of predetermined variable length channels to generate different oxygen to nitrogen flow rate ratios, i.e. different oxygen concentrations. Standard lithographic techniques were used to fabricate the microfluidic devices, using highly gas permeable silicone rubber (polydimethylsiloxane (PDMS)). The stacked microchannel architecture, channel dimensions, and layer thicknesses in the device were optimized for rapid diffusion and saturation of 02 N2 mixtures into the testing areas. The oxygen concentration was dynamically monitored using polymeric fluorescence-based oxygen sensors integrated into the device. By altering oxygen levels over time, this device aims to selectively build up biofilms on the artificial tooth substrate as the process occurs in-vitro. A study concerning this application is also presented."],"dc:description.degree":["S.B."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/43017"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Design, fabrication, and testing of a multichannel microfluidic device to dynamically control oxygen concentration conditions in-vitro"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:39Z"}