{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/40450"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/40450","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Characterization of a perfused 3D liver bioreactor","abstract":"The liver is the most important site of drug and nutrient metabolism in the body, and we desire an accurate in vitro model that allows us to perform long term drug and metabolism studies. To this end of developing an assaying tool, I used an existing multi-well bioreactor that allows for formation of perfused, three dimensional tissue structures, and began characterization of tissue behavior over time. One issue in the multi-well bioreactor is the unknown profile of cell retention over time, which is an important specification for normalizing data from drug metabolism studies. Number of cells can be indirectly assessed by measuring total protein or RNA levels when direct counting is problematic. To the end of comparing these methods, an additional goal of this thesis was to develop a protocol to measure both protein and RNA levels from a single sample using the commercially available reagent RNAlater. RNAlater was shown, however, to be incompatible with certain existing protocols for isolating both protein and RNA.","abstract_html":"The liver is the most important site of drug and nutrient metabolism in the body, and we desire an accurate in vitro model that allows us to perform long term drug and metabolism studies. To this end of developing an assaying tool, I used an existing multi-well bioreactor that allows for formation of perfused, three dimensional tissue structures, and began characterization of tissue behavior over time. One issue in the multi-well bioreactor is the unknown profile of cell retention over time, which is an important specification for normalizing data from drug metabolism studies. Number of cells can be indirectly assessed by measuring total protein or RNA levels when direct counting is problematic. To the end of comparing these methods, an additional goal of this thesis was to develop a protocol to measure both protein and RNA levels from a single sample using the commercially available reagent RNAlater. RNAlater was shown, however, to be incompatible with certain existing protocols for isolating both protein and RNA.","abstract_has_math":false,"creators":["Mitchel, Jennifer (Jennifer A.)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Linda G. Griffith."],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007","date_published":"2007","updated_at":"2026-07-22T22:21:03Z","subjects":["Mechanical Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/40450","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Linda G. Griffith."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Mitchel, Jennifer (Jennifer A.)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2008-02-27T22:27:08Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2008-02-27T22:27:08Z"]},{"key":"dc:date.issued","label":"Date","values":["2007"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/40450"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2007.","Includes bibliographical references (leaves 17-18)."]},{"key":"dc:description.abstract","label":"Abstract","values":["The liver is the most important site of drug and nutrient metabolism in the body, and we desire an accurate in vitro model that allows us to perform long term drug and metabolism studies. To this end of developing an assaying tool, I used an existing multi-well bioreactor that allows for formation of perfused, three dimensional tissue structures, and began characterization of tissue behavior over time. One issue in the multi-well bioreactor is the unknown profile of cell retention over time, which is an important specification for normalizing data from drug metabolism studies. Number of cells can be indirectly assessed by measuring total protein or RNA levels when direct counting is problematic. To the end of comparing these methods, an additional goal of this thesis was to develop a protocol to measure both protein and RNA levels from a single sample using the commercially available reagent RNAlater. RNAlater was shown, however, to be incompatible with certain existing protocols for isolating both protein and RNA."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:title","label":"Title","values":["Characterization of a perfused 3D liver bioreactor"]}]}],"canonical_facts":{"dc:contributor.advisor":["Linda G. Griffith."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Mitchel, Jennifer (Jennifer A.)"],"dc:date.accessioned":["2008-02-27T22:27:08Z"],"dc:date.available":["2008-02-27T22:27:08Z"],"dc:date.issued":["2007"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2007.","Includes bibliographical references (leaves 17-18)."],"dc:description.abstract":["The liver is the most important site of drug and nutrient metabolism in the body, and we desire an accurate in vitro model that allows us to perform long term drug and metabolism studies. To this end of developing an assaying tool, I used an existing multi-well bioreactor that allows for formation of perfused, three dimensional tissue structures, and began characterization of tissue behavior over time. One issue in the multi-well bioreactor is the unknown profile of cell retention over time, which is an important specification for normalizing data from drug metabolism studies. Number of cells can be indirectly assessed by measuring total protein or RNA levels when direct counting is problematic. To the end of comparing these methods, an additional goal of this thesis was to develop a protocol to measure both protein and RNA levels from a single sample using the commercially available reagent RNAlater. RNAlater was shown, however, to be incompatible with certain existing protocols for isolating both protein and RNA."],"dc:description.degree":["S.B."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/40450"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Characterization of a perfused 3D liver bioreactor"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:03Z"}