Back to results

Massachusetts Institute of Technology

An MRI compatible manipulator for prostate cancer detection and treatment

Abstract

dc:description.abstract

Prostate cancer is the most frequently diagnosed cancer in men and the second most common cause of cancer related death in men. Prostate specific antigen (PSA) blood tests and digital rectal exams (DRE) are preliminary tests that can suggest the presence of prostate cancer. Following these tests, a needle biopsy is required to determine if a suspected tumor is benign or malignant. Currently, an ultrasound image is used to help guide a needle to the prostate and to the suspected region. However, ultrasound images are not of good enough quality to accurately hit a tumor. Too often, false negative results are returned because the tumor is missed. This can be prevented by using more accurate images, which can be obtained using Magnetic Resonance Imaging (MRI). This presents a technical challenge because it requires robotic assistance since there is very limited access to a patient inside the bore. Additionally, the high magnetic fields prohibit the use of conventional actuators in the procedure. Dielectric Elastomer Actuators (DEAs) are MRI compatible due to their entirely polymer construction. Studies show that DEAs must be actuated in a bistable manner to be reliable. In this thesis, bistable DEAs were used in the design of an MRI compatible robotic needle manipulator.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2007

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • DeVita, Lauren M
Advisor dc:contributor.advisor
  • Steven Dubowsky.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/39869
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/39869

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

DeVita, Lauren M. An MRI compatible manipulator for prostate cancer detection and treatment. Massachusetts Institute of Technology, 2007. http://hdl.handle.net/1721.1/39869