Investigation of shear lag effect in high-rise buildings with diagrid system

Abstract

dc:description.abstract

In the recent years, there have been many new skyscrapers built which soar into new heights. The most efficient building system for high-rises has been the framed tube system. However, the framed tube building suffers from shear lag effects which cause a nonlinear distribution of axial stresses along the face of the building. A particular structural system called a diagrid system has caught the attention of the public. The diagrid system is not a new invention. The idea had been around since 1960 and few buildings have been built with the diagrid system. However, the implementation in a larger scale of such tall building was not practical due to high cost related to the difficult node connections. It is only in recent years that the technology has allowed for more reasonable cost of making the diagrid node connections. Despite becoming the new trend in high-rise structures, there are not many technical publications related to diagrid building system. A recent thesis by Moon (2005) studied the various angles of the diagrid to find optimum angle. He has also reviewed the design considerations for diagrid building. This thesis attempts to build on the study by Moon related to the shear lag effect in diagrid building. Diagrid buildings of different configuration are modeled in SAP2000 and analyzed for shear lag effect and structural performance.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Civil and Environmental Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2007

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Leonard, Johan, M. Eng. Massachusetts Institute of Technology
Advisor dc:contributor.advisor
  • Jerome J. Connor.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/39269

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Leonard, Johan, M. Eng. Massachusetts Institute of Technology. Investigation of shear lag effect in high-rise buildings with diagrid system. Massachusetts Institute of Technology, 2007. http://hdl.handle.net/1721.1/39269