Back to results

Massachusetts Institute of Technology

Reconstructing the blood pressure waveform using a wearable photoplethysmograph sensor and hydrostatic pressure variations measured by accelerometers

Abstract

dc:description.abstract

An important part of a routine clinical examination is the assessment of the arterial blood pressure waveform. The variations in shape of the waveform indicate the presence of disease. In this work, a method is developed for the reconstruction of arterial blood pressure waveform using the signals obtained from a noninvasive wearable photoplethysmographic Ring Sensor and hydrostatic pressure variations measured by an Arm Accelerometer Sensor. A dynamic model with the Wiener model structure is used to establish the relationship between transmural pressure and photoplethysmographic signal. Tuned nonlinear dynamic model has been shown to be capable of estimating the arterial blood pressure waveform. The algorithm has been applied to experimental blood pressure measurements in a healthy subject and shown to provide accurate waveform reconstruction. As a result, the use of a wearable photoplethysmographic Ring Sensor can be extended to provide a finger arterial blood pressure waveform.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2007

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Marinković, Aleksandar, S.M. Massachusetts Institute of Technology
Advisor dc:contributor.advisor
  • Haruhiko H. Asada.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/38705
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/38705

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Marinković, Aleksandar, S.M. Massachusetts Institute of Technology. Reconstructing the blood pressure waveform using a wearable photoplethysmograph sensor and hydrostatic pressure variations measured by accelerometers. Massachusetts Institute of Technology, 2007. http://hdl.handle.net/1721.1/38705