Back to results

Massachusetts Institute of Technology

Detection power, temporal response, and spatial resolution of IRON fMRI in awake, behaving monkeys at 3 Tesla

Abstract

dc:description.abstract

The main goal of this thesis was to systematically characterize the detection sensitivity, temporal response, and spatial resolution of IRON contrast for fMRI within the awake, behaving monkey. Understanding these issues provides insights into the physiology of the functional response to local changes in brain activity, enables researchers to optimize experimental designs, and delineates the advantages and limitations of neuroimaging within this important animal model. The injection of the iron oxide contrast agent (MION) provided a 9-fold increase in efficiency for block designs relatively to BOLD contrast. Because the hemodynamic response function acts as a low-pass filter on neural activation to attenuate the size of differential responses to alternate stimuli, this factor dropped to approximately 2 for rapidly presented stimuli. Detection efficiency for event-related stimulus designs for BOLD and IRON contrasts could be optimized using random or semi-random distributions for interstimulus intervals. Small increases in predictability could be traded for large gains in efficiency, particularly for the IRON method. A general linear model was successfully employed to describe IRON and BOLD impulse response functions. Both responses were accurately described by a bimodal exponential model with similar time constants, a fast (4.5 sec) and a slow (13.5 sec).

Degree

thesis:*
Department dc:contributor.department
Harvard University--MIT Division of Health Sciences and Technology
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2007

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Leite, Francisca Maria Pais Horta
Advisor dc:contributor.advisor
  • Joseph B. Mandeville.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/38593

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Leite, Francisca Maria Pais Horta. Detection power, temporal response, and spatial resolution of IRON fMRI in awake, behaving monkeys at 3 Tesla. Massachusetts Institute of Technology, 2007. http://hdl.handle.net/1721.1/38593