Back to results

Massachusetts Institute of Technology

Efficacy of Hammerstein models in capturing the dynamics of isometric muscle stimulated at various frequencies

Abstract

dc:description.abstract

Functional electrical stimulation (FES) can be employed more effectively as a rehabilitation intervention if neuroprosthetic controllers contain muscle models appropriate to the behavioral regimes of interest. The goal of this thesis is to investigate the performance of one such model, the Hammerstein cascade, in describing isometric muscle force. We examine the effectiveness of Hammerstein models in predicting the isometric recruitment curve and dynamics of a muscle stimulated at fourteen frequencies between 1 to 100Hz. Explanted frog plantaris longus muscle is tested at the nominal isometric length only; hence, the muscle's force-length and force-velocity dependences are neither assumed nor ascertained. The pilot data are fitted using ten different models consisting of various combinations of linear dynamics with polynomial nonlinearities. Models identified using data with input stimulation frequencies of 20Hz and lower generate an average RMS error of 12% and are reliably stable (87 of 90 simulations). Between 25 to 40Hz, the average error generated by the estimated models is 10%, but the estimated dynamics are less stable (16 of 30 simulations). Above 40Hz, linear and Hammerstein nonlinear models fail to consistently generate stable dynamic estimates (11 of 30 simulations), and errors are large (eRMs = 44%).

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Chou, Danielle, 1981-
Advisor dc:contributor.advisor
  • Hugh M. Herr and David L. Trumper.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/38274
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/38274

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Chou, Danielle, 1981-. Efficacy of Hammerstein models in capturing the dynamics of isometric muscle stimulated at various frequencies. Massachusetts Institute of Technology, 2006. http://hdl.handle.net/1721.1/38274