Back to results

Massachusetts Institute of Technology

The effects of electronic microscanning on infrared image aliasing and spaial resolution

Abstract

dc:description.abstract

Most modern infrared electro-optical imaging systems utilize staring imagers to acquire image data. Typical staring focal plane arrays contain a two-dimensional array of photodetectors. Each photodetector generates an electrical current or charge proportional to the number of photons striking its immediate vicinity. However, due to the discrete finite nature of the FPA detector lattice and fact that each photodetector's collection area is matched to the optical blur for signal to noise considerations, the imager does not satisfy the Nyquist criteria for sampling systems. Consequently, aliasing effects are usually an inherent part of images produced by staring arrays. Microscanning is a method which can be used to reduce spatial frequency aliasing within an image by spatially oversampling the image scene. During the microscanning process, several optically dithered subimages are acquired and combined to create a larger image. The resulting image will have a higher sampling rate, and accordingly a greater Nyquist cutoff frequency, with the same spatial frequency resolution and optical cutoff frequency. This thesis discusses the effects of a novel approach to the microscanning operation, called electronic microscanning. The electronic microscanning device performs the microscan operation by shifting the collection area of each pixel in the array by half-pixel increments instead of utilizing mechanical or liquid crystal filters to deflect the image. Electronic microscanning has an inherent advantage over traditional microscanning systems since no scanners or moving parts are needed to oversample the image. A model of the electronic microscan device is developed and compared to prototype laboratory results obtained at the Raytheon Company Electro-Optics Laboratory in Tewksbury, Massachusetts.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
1995

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wexler, Howard Jay
Advisor dc:contributor.advisor
  • William Clem Karl and Thomas R. Briere.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/37814
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/37814

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Wexler, Howard Jay. The effects of electronic microscanning on infrared image aliasing and spaial resolution. Massachusetts Institute of Technology, 1995. http://hdl.handle.net/1721.1/37814