{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/37208"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/37208","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Design and evaluation of a 2-D planar therapeutic ultrasound phased array","abstract":"Focused ultrasound continues to be investigated as an exciting technique for several medical therapy applications including tissue ablation. Phased array transducers serve as important devices for delivering the high intensity focused ultrasound to the targeted tissue. These arrays often produce undesired secondary foci called grating lobes that can result in heating of non-targeted healthy tissue. Grating lobes can be eliminated by setting the element-spacing between adjacent elements to 2 or less. The aim of this research is to construct and evaluate a 2-D planar phased array with close to /2 element-spacing. A 7x7 element array with element-spacing of 0.762mm was constructed using 1,3-piezocomposite material. Acoustic field measurements of the array focused at three different locations were taken to demonstrate its ability to scan the focus in a volume. In addition, a maximum average intensity of 5.54W/cm2 was measured for the unfocused array using radiation force measurements.","abstract_html":"Focused ultrasound continues to be investigated as an exciting technique for several medical therapy applications including tissue ablation. Phased array transducers serve as important devices for delivering the high intensity focused ultrasound to the targeted tissue. These arrays often produce undesired secondary foci called grating lobes that can result in heating of non-targeted healthy tissue. Grating lobes can be eliminated by setting the element-spacing between adjacent elements to 2 or less. The aim of this research is to construct and evaluate a 2-D planar phased array with close to /2 element-spacing. A 7x7 element array with element-spacing of 0.762mm was constructed using 1,3-piezocomposite material. Acoustic field measurements of the array focused at three different locations were taken to demonstrate its ability to scan the focus in a volume. In addition, a maximum average intensity of 5.54W/cm2 was measured for the unfocused array using radiation force measurements.","abstract_has_math":false,"creators":["Khatri, Danish Suleiman"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.","school":null,"contributors":[],"advisors":["Kullervo Hynynen and Roger G. Mark."],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006","date_published":"2006","updated_at":"2026-07-22T22:21:57Z","subjects":["Electrical Engineering and Computer Science."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/37208","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kullervo Hynynen and Roger G. Mark."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Khatri, Danish Suleiman"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-04-20T15:50:14Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-04-20T15:50:14Z"]},{"key":"dc:date.issued","label":"Date","values":["2006"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/37208"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, February 2006.","\"October 14, 2005.\"","Includes bibliographical references (leaves 63-67)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Focused ultrasound continues to be investigated as an exciting technique for several medical therapy applications including tissue ablation. Phased array transducers serve as important devices for delivering the high intensity focused ultrasound to the targeted tissue. These arrays often produce undesired secondary foci called grating lobes that can result in heating of non-targeted healthy tissue. Grating lobes can be eliminated by setting the element-spacing between adjacent elements to 2 or less. The aim of this research is to construct and evaluate a 2-D planar phased array with close to /2 element-spacing. A 7x7 element array with element-spacing of 0.762mm was constructed using 1,3-piezocomposite material. Acoustic field measurements of the array focused at three different locations were taken to demonstrate its ability to scan the focus in a volume. In addition, a maximum average intensity of 5.54W/cm2 was measured for the unfocused array using radiation force measurements."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.Eng."]},{"key":"dc:title","label":"Title","values":["Design and evaluation of a 2-D planar therapeutic ultrasound phased array"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kullervo Hynynen and Roger G. Mark."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."],"dc:creator":["Khatri, Danish Suleiman"],"dc:date.accessioned":["2007-04-20T15:50:14Z"],"dc:date.available":["2007-04-20T15:50:14Z"],"dc:date.issued":["2006"],"dc:description":["Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, February 2006.","\"October 14, 2005.\"","Includes bibliographical references (leaves 63-67)."],"dc:description.abstract":["Focused ultrasound continues to be investigated as an exciting technique for several medical therapy applications including tissue ablation. Phased array transducers serve as important devices for delivering the high intensity focused ultrasound to the targeted tissue. These arrays often produce undesired secondary foci called grating lobes that can result in heating of non-targeted healthy tissue. Grating lobes can be eliminated by setting the element-spacing between adjacent elements to 2 or less. The aim of this research is to construct and evaluate a 2-D planar phased array with close to /2 element-spacing. A 7x7 element array with element-spacing of 0.762mm was constructed using 1,3-piezocomposite material. Acoustic field measurements of the array focused at three different locations were taken to demonstrate its ability to scan the focus in a volume. In addition, a maximum average intensity of 5.54W/cm2 was measured for the unfocused array using radiation force measurements."],"dc:description.degree":["M.Eng."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/37208"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["Design and evaluation of a 2-D planar therapeutic ultrasound phased array"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:57Z"}