{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/36693"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/36693","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Design of a novel anterior cruciate ligament prosthesis","abstract":"Injuries to the anterior cruciate ligament (ACL) are extremely common (approximately 100,000 every year in the US) and result in greatly reduced mobility; although several surgical procedures have been devised to address this condition, they are far from being completely satisfactory. The golden standard is currently represented by tendon autografts which, however, result in considerable donor site morbidity. An ideal solution would be to use effective, off-the-shelf permanent prostheses: however, all such devices proposed to date have proved highly disappointing, because of poor long term stability and biocompatibility, and unphysiological mechanical behavior. To address both concerns a novel prosthetic device has been developed, employing crimped NiTi superelastic wire bundles. To achieve near-physiological mechanical behavior, the fiber geometry resembles (on a much larger scale) that of the collagen fibrils that naturally make up the ligament, using as a starting point the Comninou-Yannas crimped-fiber model.","abstract_html":"Injuries to the anterior cruciate ligament (ACL) are extremely common (approximately 100,000 every year in the US) and result in greatly reduced mobility; although several surgical procedures have been devised to address this condition, they are far from being completely satisfactory. The golden standard is currently represented by tendon autografts which, however, result in considerable donor site morbidity. An ideal solution would be to use effective, off-the-shelf permanent prostheses: however, all such devices proposed to date have proved highly disappointing, because of poor long term stability and biocompatibility, and unphysiological mechanical behavior. To address both concerns a novel prosthetic device has been developed, employing crimped NiTi superelastic wire bundles. To achieve near-physiological mechanical behavior, the fiber geometry resembles (on a much larger scale) that of the collagen fibrils that naturally make up the ligament, using as a starting point the Comninou-Yannas crimped-fiber model.","abstract_has_math":false,"creators":["Talei Franzesi, Giovanni"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Myron Spector and Ioannis V. Yannas."],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006","date_published":"2006","updated_at":"2026-07-22T22:21:44Z","subjects":["Mechanical Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/36693","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Myron Spector and Ioannis V. Yannas."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Talei Franzesi, Giovanni"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-03-12T17:45:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-03-12T17:45:02Z"]},{"key":"dc:date.issued","label":"Date","values":["2006"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/36693"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2006.","Includes bibliographical references (p. 17-19)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Injuries to the anterior cruciate ligament (ACL) are extremely common (approximately 100,000 every year in the US) and result in greatly reduced mobility; although several surgical procedures have been devised to address this condition, they are far from being completely satisfactory. The golden standard is currently represented by tendon autografts which, however, result in considerable donor site morbidity. An ideal solution would be to use effective, off-the-shelf permanent prostheses: however, all such devices proposed to date have proved highly disappointing, because of poor long term stability and biocompatibility, and unphysiological mechanical behavior. To address both concerns a novel prosthetic device has been developed, employing crimped NiTi superelastic wire bundles. To achieve near-physiological mechanical behavior, the fiber geometry resembles (on a much larger scale) that of the collagen fibrils that naturally make up the ligament, using as a starting point the Comninou-Yannas crimped-fiber model.","(cont.) NiTi (a superelastic alloy of titanium and nickel) has been tested and employed in a variety of biomedical settings and its excellent wear and biocompatibility characteristics make it a superior candidate for this application; the relevant literature has been reviewed and assessed. A detailed design for such prosthesis has been proposed, and a proof-of-principle model of the fiber geometry built and tested. The results obtained to date are encouraging and further testing, with a NiTi prototype should be carried out to validate our proposed design."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:title","label":"Title","values":["Design of a novel anterior cruciate ligament prosthesis"]}]}],"canonical_facts":{"dc:contributor.advisor":["Myron Spector and Ioannis V. Yannas."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Talei Franzesi, Giovanni"],"dc:date.accessioned":["2007-03-12T17:45:02Z"],"dc:date.available":["2007-03-12T17:45:02Z"],"dc:date.issued":["2006"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2006.","Includes bibliographical references (p. 17-19)."],"dc:description.abstract":["Injuries to the anterior cruciate ligament (ACL) are extremely common (approximately 100,000 every year in the US) and result in greatly reduced mobility; although several surgical procedures have been devised to address this condition, they are far from being completely satisfactory. The golden standard is currently represented by tendon autografts which, however, result in considerable donor site morbidity. An ideal solution would be to use effective, off-the-shelf permanent prostheses: however, all such devices proposed to date have proved highly disappointing, because of poor long term stability and biocompatibility, and unphysiological mechanical behavior. To address both concerns a novel prosthetic device has been developed, employing crimped NiTi superelastic wire bundles. To achieve near-physiological mechanical behavior, the fiber geometry resembles (on a much larger scale) that of the collagen fibrils that naturally make up the ligament, using as a starting point the Comninou-Yannas crimped-fiber model.","(cont.) NiTi (a superelastic alloy of titanium and nickel) has been tested and employed in a variety of biomedical settings and its excellent wear and biocompatibility characteristics make it a superior candidate for this application; the relevant literature has been reviewed and assessed. A detailed design for such prosthesis has been proposed, and a proof-of-principle model of the fiber geometry built and tested. The results obtained to date are encouraging and further testing, with a NiTi prototype should be carried out to validate our proposed design."],"dc:description.degree":["S.B."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/36693"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Design of a novel anterior cruciate ligament prosthesis"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:44Z"}