Back to results

Massachusetts Institute of Technology

Mechanical and biochemical properties of human cervical tissue

Abstract

dc:description.abstract

The mechanical integrity of cervical tissue is crucial for maintaining a healthy gestation. Altered tissue biochemistry can cause drastic changes in the mechanical properties of the cervix and contribute to premature cervical dilation and delivery. This work presents an investigation of the mechanical and biochemical properties of cervical samples from human hysterectomy specimens. Three clinical cases were investigated: non-pregnant hysterectomy patients with previous vaginal deliveries, non-pregnant hysterectomy patients with no previous vaginal deliveries, and pregnant hysterectomy patients at time of cesarean section. Tissue samples for the three clinical cases were tested mechanically and analyzed for biochemical content. Tissue samples were tested in confined and unconfined compression, and biochemical assays measured cervical tissue hydration, collagen content, collagen extractability, and sulfated glycosaminoglycan content. The non-pregnant tissue was found to be significantly stiffer than the pregnant tissue. Collagen extractability was significantly higher in the pregnant tissue. This study represents a first important step towards the attainment of an improved understanding of the complex interplay between the molecular structure of cervical tissue and its macroscopic mechanical properties.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Myers, Kristin M
Advisor dc:contributor.advisor
  • Simona Socrate.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/36196
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/36196

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Myers, Kristin M. Mechanical and biochemical properties of human cervical tissue. Massachusetts Institute of Technology, 2005. http://hdl.handle.net/1721.1/36196