Back to results

Massachusetts Institute of Technology

An analog VLSI front end for pulse oximetry

Abstract

dc:description.abstract

Pulse oximetry is a fast, noninvasive, easy-to-use, and continuous method for monitoring the oxygen saturation of a patient's blood. In modem medical practice, blood oxygen level is considered one of the important vital signs of the body. The pulse oximeter system consists of an optoelectronic sensor that is normally placed on the subject's finger and a signal processing unit that computes the oxygen saturation. It uses red and infrared LEDs to illuminate the subject's finger. We present an advanced logarithmic photoreceptor which takes advantage of techniques such as distributed (cascaded) amplification, automatic loop gain control, and parasitic capacitance unilateralization to improve the performance and ameliorate certain shortcomings of existing logarithmic photoreceptors. These improvements allow us to reduce LED power significantly because of a more sensitive photoreceptor. Furthermore, the exploitation of the logarithmic nonlinearity inherent in transistors eliminates the need of performing some of the mathematical operations which are traditionally done in digital domain to calculate oxygen saturation and allows for a very area-efficient all-analog implementation. The need for an ADC and a DSP is thus completely eliminated.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Tavakoli Dastjerdi, Maziar, 1976-
Advisor dc:contributor.advisor
  • Rahul Sarpeshkar.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/36184
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/36184

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Tavakoli Dastjerdi, Maziar, 1976-. An analog VLSI front end for pulse oximetry. Massachusetts Institute of Technology, 2006. http://hdl.handle.net/1721.1/36184