{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/35671"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/35671","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Instrumentation for multiaxial mechanical testing of inhomogeneous elastic membranes","abstract":"This thesis presents the design, development, and construction of an instrument for biaxial mechanical testing of inhomogeneous elastic membranes. The instrument incorporates an arrangement of linear motion stages for applying arbitrary deformation profiles on the material under test, purpose-built two-axis force transducers for high-resolution measurement of applied loads, and a digital imaging system for full-field strain measurement. The components described herein provide the foundation for a sophisticated biaxial testing platform for determining the mechanical properties of anisotropic, inhomogeneous membrane materials.","abstract_html":"This thesis presents the design, development, and construction of an instrument for biaxial mechanical testing of inhomogeneous elastic membranes. The instrument incorporates an arrangement of linear motion stages for applying arbitrary deformation profiles on the material under test, purpose-built two-axis force transducers for high-resolution measurement of applied loads, and a digital imaging system for full-field strain measurement. The components described herein provide the foundation for a sophisticated biaxial testing platform for determining the mechanical properties of anisotropic, inhomogeneous membrane materials.","abstract_has_math":false,"creators":["Herrmann, Ariel Marc"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Ian W. Hunter."],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006","date_published":"2006","updated_at":"2026-07-22T22:22:18Z","subjects":["Mechanical Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/35671","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ian W. Hunter."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Herrmann, Ariel Marc"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-01-10T16:59:59Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-01-10T16:59:59Z"]},{"key":"dc:date.issued","label":"Date","values":["2006"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/35671"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2006.","Includes bibliographical references (p. 93-100)."]},{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents the design, development, and construction of an instrument for biaxial mechanical testing of inhomogeneous elastic membranes. The instrument incorporates an arrangement of linear motion stages for applying arbitrary deformation profiles on the material under test, purpose-built two-axis force transducers for high-resolution measurement of applied loads, and a digital imaging system for full-field strain measurement. The components described herein provide the foundation for a sophisticated biaxial testing platform for determining the mechanical properties of anisotropic, inhomogeneous membrane materials."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Instrumentation for multiaxial mechanical testing of inhomogeneous elastic membranes"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ian W. Hunter."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Herrmann, Ariel Marc"],"dc:date.accessioned":["2007-01-10T16:59:59Z"],"dc:date.available":["2007-01-10T16:59:59Z"],"dc:date.issued":["2006"],"dc:description":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2006.","Includes bibliographical references (p. 93-100)."],"dc:description.abstract":["This thesis presents the design, development, and construction of an instrument for biaxial mechanical testing of inhomogeneous elastic membranes. The instrument incorporates an arrangement of linear motion stages for applying arbitrary deformation profiles on the material under test, purpose-built two-axis force transducers for high-resolution measurement of applied loads, and a digital imaging system for full-field strain measurement. The components described herein provide the foundation for a sophisticated biaxial testing platform for determining the mechanical properties of anisotropic, inhomogeneous membrane materials."],"dc:description.degree":["S.M."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/35671"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Instrumentation for multiaxial mechanical testing of inhomogeneous elastic membranes"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:22:18Z"}