Massachusetts Institute of Technology
Approaches to optimal inertial instrument calibration using slewing
Abstract
dc:description.abstractCalibration of an inertial measurement unit is important to the success of accuracy-sensitive missions. This thesis analyzes calibration techniques for two inertial measurement mechanizations: (1) an inertially stabilized system and (2) an inertially referenced slew. An inertially referenced slew rotates the inertial measurement unit with respect to an inertial reference frame independent of the vehicle motion. The appropriate inertially referenced slew is determined by a proposed optimal calibration method that maximizes the correlation between a measurement and a covector, specifying a mission performance index. The performances of a six-position dwell calibration (inertially stabilized system) and an optimal slewing calibration (inertially referenced slew) are determined to be dependent on the mission. The inertially stabilized system is preferred for determining accelerometer errors and an inertially referenced slew is preferred for calibrating rate-sensitive gyroscope errors.
Degree
thesis:*- Department dc:contributor.department
- Massachusetts Institute of Technology. Dept. of Aeronautics and Astronautics.
- Grantor dc:publisher
- Massachusetts Institute of Technology
- Year dc:date.issued
- 2005
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Becker, Theresia Caezilia
- Advisor dc:contributor.advisor
-
- Matthew Bottkol and George Schmidt.
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
- Licence dc:rights.uri
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- http://hdl.handle.net/1721.1/34142
- OAI identifier oai:identifier
- oai:dspace.mit.edu:1721.1/34142