{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/34132"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/34132","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Characterization and control of a robot for wrist rehabilitation","abstract":"Human motor control pathologies, such as those caused by stroke, can be treated through physical rehabilitation. The use of robots in therapy environments seems appropriate considering the possibilities they offer for quantification of performance as well as \"quality control\" between therapy sessions. The research presented in this thesis is part of the continuing development of robotic applications for physical therapy and neuro-rehabilitation at the Newman Laboratory for Biomechanics and Human Rehabilitation. MIT-MANUS, a robot for shoulder and elbow therapy developed in this lab, introduced this new brand of therapy, offering a highly backdrivable mechanism with a soft and stable feel for the user. The focus here is the development, characterization, and implementation of a robot for wrist rehabilitation, designed to provide three rotational degrees of freedom. The wrist motions of flexion/extension and abduction/adduction are governed by a differential gear mechanism, while pronation and supination of the forearm are actuated by a curved slider attached to the rest of the mechanism. Through the characterization, the device was found to exhibit some unwanted behavior, largely attributable to the nonlinearities inherent in the system. Efforts to suppress these effects through control are presented along with recommendations for addressing these problems at the design level.","abstract_html":"Human motor control pathologies, such as those caused by stroke, can be treated through physical rehabilitation. The use of robots in therapy environments seems appropriate considering the possibilities they offer for quantification of performance as well as &quot;quality control&quot; between therapy sessions. The research presented in this thesis is part of the continuing development of robotic applications for physical therapy and neuro-rehabilitation at the Newman Laboratory for Biomechanics and Human Rehabilitation. MIT-MANUS, a robot for shoulder and elbow therapy developed in this lab, introduced this new brand of therapy, offering a highly backdrivable mechanism with a soft and stable feel for the user. The focus here is the development, characterization, and implementation of a robot for wrist rehabilitation, designed to provide three rotational degrees of freedom. The wrist motions of flexion/extension and abduction/adduction are governed by a differential gear mechanism, while pronation and supination of the forearm are actuated by a curved slider attached to the rest of the mechanism. Through the characterization, the device was found to exhibit some unwanted behavior, largely attributable to the nonlinearities inherent in the system. Efforts to suppress these effects through control are presented along with recommendations for addressing these problems at the design level.","abstract_has_math":false,"creators":["Celestino, James R. (James Richard)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Neville Hogan."],"committee_chairs":[],"committee_members":[],"year":2003,"date_issued":"2003","date_published":"2003","updated_at":"2026-07-22T22:21:24Z","subjects":["Mechanical Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/34132","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Neville Hogan."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Celestino, James R. (James Richard)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-09-28T15:06:17Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-09-28T15:06:17Z"]},{"key":"dc:date.issued","label":"Date","values":["2003"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/34132"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2003.","Includes bibliographical references (p. 209-214)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Human motor control pathologies, such as those caused by stroke, can be treated through physical rehabilitation. The use of robots in therapy environments seems appropriate considering the possibilities they offer for quantification of performance as well as \"quality control\" between therapy sessions. The research presented in this thesis is part of the continuing development of robotic applications for physical therapy and neuro-rehabilitation at the Newman Laboratory for Biomechanics and Human Rehabilitation. MIT-MANUS, a robot for shoulder and elbow therapy developed in this lab, introduced this new brand of therapy, offering a highly backdrivable mechanism with a soft and stable feel for the user. The focus here is the development, characterization, and implementation of a robot for wrist rehabilitation, designed to provide three rotational degrees of freedom. The wrist motions of flexion/extension and abduction/adduction are governed by a differential gear mechanism, while pronation and supination of the forearm are actuated by a curved slider attached to the rest of the mechanism. Through the characterization, the device was found to exhibit some unwanted behavior, largely attributable to the nonlinearities inherent in the system. Efforts to suppress these effects through control are presented along with recommendations for addressing these problems at the design level.","(cont.) The alpha prototype has been set up for clinical trials by providing a functional control scheme along with \"video game\" patient interfaces; initial clinical trials will run in parallel with the development of the next version of the device. If improvements comparable to those seen with the use of MIT-MANUS are seen with the wrist robot, then rehabilitation therapists will have a new and useful tool at their disposal."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Characterization and control of a robot for wrist rehabilitation"]}]}],"canonical_facts":{"dc:contributor.advisor":["Neville Hogan."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Celestino, James R. (James Richard)"],"dc:date.accessioned":["2006-09-28T15:06:17Z"],"dc:date.available":["2006-09-28T15:06:17Z"],"dc:date.issued":["2003"],"dc:description":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2003.","Includes bibliographical references (p. 209-214)."],"dc:description.abstract":["Human motor control pathologies, such as those caused by stroke, can be treated through physical rehabilitation. The use of robots in therapy environments seems appropriate considering the possibilities they offer for quantification of performance as well as \"quality control\" between therapy sessions. The research presented in this thesis is part of the continuing development of robotic applications for physical therapy and neuro-rehabilitation at the Newman Laboratory for Biomechanics and Human Rehabilitation. MIT-MANUS, a robot for shoulder and elbow therapy developed in this lab, introduced this new brand of therapy, offering a highly backdrivable mechanism with a soft and stable feel for the user. The focus here is the development, characterization, and implementation of a robot for wrist rehabilitation, designed to provide three rotational degrees of freedom. The wrist motions of flexion/extension and abduction/adduction are governed by a differential gear mechanism, while pronation and supination of the forearm are actuated by a curved slider attached to the rest of the mechanism. Through the characterization, the device was found to exhibit some unwanted behavior, largely attributable to the nonlinearities inherent in the system. Efforts to suppress these effects through control are presented along with recommendations for addressing these problems at the design level.","(cont.) The alpha prototype has been set up for clinical trials by providing a functional control scheme along with \"video game\" patient interfaces; initial clinical trials will run in parallel with the development of the next version of the device. If improvements comparable to those seen with the use of MIT-MANUS are seen with the wrist robot, then rehabilitation therapists will have a new and useful tool at their disposal."],"dc:description.degree":["S.M."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/34132"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Characterization and control of a robot for wrist rehabilitation"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:24Z"}