{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/33707"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/33707","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Graphical interface for quantitative monitoring of 3D MRI data","abstract":"The recent development of techniques in magnetic resonance imaging allows for the noninvasive monitoring of cartilage for disease progression, effects of lifestyle change, and results of medical interventions. In particular, the dGEMRIC technique has been used. Prior dGEMRIC data have been two-dimensional. Magnetic resonance equipment can currently produce three-dimensional dGEMRIC data, but software that analyzes three-dimensional data sets is lacking in practicality. This research improved existing software to better handle three-dimensional dGEMRIC data sets. Improvements were made to better facilitate (1) image section selection, (2) segmentation, (3) T1 mapping, and (4) statistical data analysis.","abstract_html":"The recent development of techniques in magnetic resonance imaging allows for the noninvasive monitoring of cartilage for disease progression, effects of lifestyle change, and results of medical interventions. In particular, the dGEMRIC technique has been used. Prior dGEMRIC data have been two-dimensional. Magnetic resonance equipment can currently produce three-dimensional dGEMRIC data, but software that analyzes three-dimensional data sets is lacking in practicality. This research improved existing software to better handle three-dimensional dGEMRIC data sets. Improvements were made to better facilitate (1) image section selection, (2) segmentation, (3) T1 mapping, and (4) statistical data analysis.","abstract_has_math":false,"creators":["Gerber, Meredith L"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.","school":null,"contributors":[],"advisors":["Deborah Burstein."],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005","date_published":"2005","updated_at":"2026-07-22T22:21:24Z","subjects":["Electrical Engineering and Computer Science."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/33707","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Deborah Burstein."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Gerber, Meredith L"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-07-31T15:25:58Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-07-31T15:25:58Z"]},{"key":"dc:date.issued","label":"Date","values":["2005"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/33707"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2005.","Includes bibliographical references (leaf 62)."]},{"key":"dc:description.abstract","label":"Abstract","values":["The recent development of techniques in magnetic resonance imaging allows for the noninvasive monitoring of cartilage for disease progression, effects of lifestyle change, and results of medical interventions. In particular, the dGEMRIC technique has been used. Prior dGEMRIC data have been two-dimensional. Magnetic resonance equipment can currently produce three-dimensional dGEMRIC data, but software that analyzes three-dimensional data sets is lacking in practicality. This research improved existing software to better handle three-dimensional dGEMRIC data sets. Improvements were made to better facilitate (1) image section selection, (2) segmentation, (3) T1 mapping, and (4) statistical data analysis."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.Eng."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Graphical interface for quantitative monitoring of 3D MRI data"]}]}],"canonical_facts":{"dc:contributor.advisor":["Deborah Burstein."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."],"dc:creator":["Gerber, Meredith L"],"dc:date.accessioned":["2006-07-31T15:25:58Z"],"dc:date.available":["2006-07-31T15:25:58Z"],"dc:date.issued":["2005"],"dc:description":["Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2005.","Includes bibliographical references (leaf 62)."],"dc:description.abstract":["The recent development of techniques in magnetic resonance imaging allows for the noninvasive monitoring of cartilage for disease progression, effects of lifestyle change, and results of medical interventions. In particular, the dGEMRIC technique has been used. Prior dGEMRIC data have been two-dimensional. Magnetic resonance equipment can currently produce three-dimensional dGEMRIC data, but software that analyzes three-dimensional data sets is lacking in practicality. This research improved existing software to better handle three-dimensional dGEMRIC data sets. Improvements were made to better facilitate (1) image section selection, (2) segmentation, (3) T1 mapping, and (4) statistical data analysis."],"dc:description.degree":["M.Eng."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/33707"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["Graphical interface for quantitative monitoring of 3D MRI data"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:24Z"}