Back to results

Massachusetts Institute of Technology

Physiological Sensor System for a wireless tactile display

Abstract

dc:description.abstract

This research focuses on the development of a wearable Physiological Sensor System (PSS) that can be used with a wireless tactile control unit to monitor the physiological status of a mobile user. Two physiological variables, heart rate and respiration rate, were selected for initial study, and technologies that could be used to measure these variables were evaluated. The PSS was required to be non-invasive, lightweight, and low-power. Initial studies indicated that heart rate could be most effectively measured using infrared light technology and so this was implemented in a wrist strap. It was determined that respiration rate could be recorded using a novel implementation of conducting polymer strain gages. For this purpose, polypyrrole-coated Lycra was fabricated and a chest strap was made that incorporated this sensor for recording respiration rate. Both sensors were connected to the PSS unit that was designed to provide the necessary signal processing, such as filtering and amplification, as well as produce the digital output signals that could be analyzed by the microcontroller in the tactile control unit. The complete circuit design process is described, from initial prototype development and testing to final layout and printed circuit board fabrication.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Deo, Nikhila
Advisor dc:contributor.advisor
  • Lynette A. Jones.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/33121
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/33121

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Deo, Nikhila. Physiological Sensor System for a wireless tactile display. Massachusetts Institute of Technology, 2005. http://hdl.handle.net/1721.1/33121