{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/32882"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/32882","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"An autocorrelator-interferometer used to determine the pulse width of a pulsed laser used in two-photon endoscopy","abstract":"An autocorrelator-inferometer was designed to correctly assess the pulse width of pulse laser used in two photon endoscopy. The path length of the light was altered using a retro-reflecting corner cube attached to a 6880 galvanometer optical scanner controlled by a 671 series micro-max controller (both products by Cambridge Technologies Inc.) The scanner was selected due to its ability to traverse very small rotations with a constant angular velocity, thereby reducing any non-linearities (with respect to time) in the autocorrelation. The projected results of this autocorrelator suggest it can be used to analyze electromagnetic waves with pulses on the order of a couple picoseconds, however, due to an imbalance of the scanner's shaft, the device was broken before any tests could be performed. A preliminary analysis suggests that a circular shaft attachment could be used to prevent this problem in the future.","abstract_html":"An autocorrelator-inferometer was designed to correctly assess the pulse width of pulse laser used in two photon endoscopy. The path length of the light was altered using a retro-reflecting corner cube attached to a 6880 galvanometer optical scanner controlled by a 671 series micro-max controller (both products by Cambridge Technologies Inc.) The scanner was selected due to its ability to traverse very small rotations with a constant angular velocity, thereby reducing any non-linearities (with respect to time) in the autocorrelation. The projected results of this autocorrelator suggest it can be used to analyze electromagnetic waves with pulses on the order of a couple picoseconds, however, due to an imbalance of the scanner&#x27;s shaft, the device was broken before any tests could be performed. A preliminary analysis suggests that a circular shaft attachment could be used to prevent this problem in the future.","abstract_has_math":false,"creators":["Baksh, Nicholas A. (Nicholas Anwar)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Peter So."],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005","date_published":"2005","updated_at":"2026-07-22T22:21:30Z","subjects":["Mechanical Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/32882","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Peter So."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Baksh, Nicholas A. (Nicholas Anwar)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-05-15T20:36:45Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-05-15T20:36:45Z"]},{"key":"dc:date.issued","label":"Date","values":["2005"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/32882"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, June 2005.","\"May 2005.\"","Includes bibliographical references (leaf 9)."]},{"key":"dc:description.abstract","label":"Abstract","values":["An autocorrelator-inferometer was designed to correctly assess the pulse width of pulse laser used in two photon endoscopy. The path length of the light was altered using a retro-reflecting corner cube attached to a 6880 galvanometer optical scanner controlled by a 671 series micro-max controller (both products by Cambridge Technologies Inc.) The scanner was selected due to its ability to traverse very small rotations with a constant angular velocity, thereby reducing any non-linearities (with respect to time) in the autocorrelation. The projected results of this autocorrelator suggest it can be used to analyze electromagnetic waves with pulses on the order of a couple picoseconds, however, due to an imbalance of the scanner's shaft, the device was broken before any tests could be performed. A preliminary analysis suggests that a circular shaft attachment could be used to prevent this problem in the future."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["An autocorrelator-interferometer used to determine the pulse width of a pulsed laser used in two-photon endoscopy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Peter So."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Baksh, Nicholas A. (Nicholas Anwar)"],"dc:date.accessioned":["2006-05-15T20:36:45Z"],"dc:date.available":["2006-05-15T20:36:45Z"],"dc:date.issued":["2005"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, June 2005.","\"May 2005.\"","Includes bibliographical references (leaf 9)."],"dc:description.abstract":["An autocorrelator-inferometer was designed to correctly assess the pulse width of pulse laser used in two photon endoscopy. The path length of the light was altered using a retro-reflecting corner cube attached to a 6880 galvanometer optical scanner controlled by a 671 series micro-max controller (both products by Cambridge Technologies Inc.) The scanner was selected due to its ability to traverse very small rotations with a constant angular velocity, thereby reducing any non-linearities (with respect to time) in the autocorrelation. The projected results of this autocorrelator suggest it can be used to analyze electromagnetic waves with pulses on the order of a couple picoseconds, however, due to an imbalance of the scanner's shaft, the device was broken before any tests could be performed. A preliminary analysis suggests that a circular shaft attachment could be used to prevent this problem in the future."],"dc:description.degree":["S.B."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/32882"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["An autocorrelator-interferometer used to determine the pulse width of a pulsed laser used in two-photon endoscopy"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:30Z"}