Back to results

Massachusetts Institute of Technology

Calibration of sonographic gel probe covers for in-vivo mechanical testing

Abstract

dc:description.abstract

Cervical insufficiency is a condition in pregnancy in which the cervix asymptomatically dilates in the absence of uterine contractions, resulting in a spontaneous preterm delivery. The condition is often misdiagnosed and presents a significant challenge for the clinical community. In order to establish better diagnostic criteria for cervical insufficiency and to improve assessment of preterm delivery risk for the individual patient, a non-invasive medical imaging tool, which uses ultrasound elastography to test the mechanical properties of cervical tissue, has been developed. The hand-held ultrasound indentation system will enable in vivo collection of stress-strain data from patients that will provide researchers with the necessary information to be used in material modeling and improve diagnosis of cervical insufficiency. The device consists of an ultrasound probe, enclosed by a gel-filled cover. The mechanical properties of the covers vary with each cap as well as with time and temperature. Therefore, in order to ensure accurate measurement, the probe covers must be calibrated prior to use. An experimental study was carried out to examine the effects of various testing conditions on the mechanical behavior of the probe covers. Different freezing and thawing techniques were explored in order to determine favorable conditions in order to preserve the integrity of the probes between the time of manufacture and actual use. From the results of the research, the appropriate combination of testing conditions for probe calibration was determined, as well as freezing and thawing techniques for probe preservation.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Charenkavanich, Panasaya
Advisor dc:contributor.advisor
  • Simona Socrate.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/32870
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/32870

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Charenkavanich, Panasaya. Calibration of sonographic gel probe covers for in-vivo mechanical testing. Massachusetts Institute of Technology, 2005. http://hdl.handle.net/1721.1/32870