{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/32828"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/32828","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Development of tissue printed nitrocellulose cards/arrays for real time PCR amplification and detection","abstract":"Tissue print technology allows for the transfer of cellular material from tissue onto a nitrocellulose film for immunocytochemical assays. The MIT BioInstrumentation Laboratory is currently developing a novel cancer marker imaging system for detection of cancerous tissue, which will be useful for discerning tumor margins. This research will advance the recent application of tissue print technology in bio-medicine by combining it with imaging and real time polymerase chain reaction (PCR) amplification and detection. A major objective in the design of this instrumentation is to develop the capacity to evaluate much larger areas of tissue. An approach to fulfilling this objective is the creation of a gasket that can seal individual wells of a nitrocellulose array. A gasket was created by laser cutting an assembly of molded silicone rubber and a double-sided tape (silicone-acrylic). Experiments showed when the gasket was adhered to a glass slide and subjected to the PCR, there was no leakage. FAST Slides, nitrocellulose slides provided by Grace Bio-Labs, are cut with a laser to generate the nitrocellulose arrays.","abstract_html":"Tissue print technology allows for the transfer of cellular material from tissue onto a nitrocellulose film for immunocytochemical assays. The MIT BioInstrumentation Laboratory is currently developing a novel cancer marker imaging system for detection of cancerous tissue, which will be useful for discerning tumor margins. This research will advance the recent application of tissue print technology in bio-medicine by combining it with imaging and real time polymerase chain reaction (PCR) amplification and detection. A major objective in the design of this instrumentation is to develop the capacity to evaluate much larger areas of tissue. An approach to fulfilling this objective is the creation of a gasket that can seal individual wells of a nitrocellulose array. A gasket was created by laser cutting an assembly of molded silicone rubber and a double-sided tape (silicone-acrylic). Experiments showed when the gasket was adhered to a glass slide and subjected to the PCR, there was no leakage. FAST Slides, nitrocellulose slides provided by Grace Bio-Labs, are cut with a laser to generate the nitrocellulose arrays.","abstract_has_math":false,"creators":["Chia, Helena Nien-Hwa, 1982-"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Ian Hunter."],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004","date_published":"2004","updated_at":"2026-07-22T22:21:05Z","subjects":["Mechanical Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/32828","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ian Hunter."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Chia, Helena Nien-Hwa, 1982-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-05-15T20:33:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-05-15T20:33:02Z"]},{"key":"dc:date.issued","label":"Date","values":["2004"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/32828"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2004.","Includes bibliographical references (leaf 21)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Tissue print technology allows for the transfer of cellular material from tissue onto a nitrocellulose film for immunocytochemical assays. The MIT BioInstrumentation Laboratory is currently developing a novel cancer marker imaging system for detection of cancerous tissue, which will be useful for discerning tumor margins. This research will advance the recent application of tissue print technology in bio-medicine by combining it with imaging and real time polymerase chain reaction (PCR) amplification and detection. A major objective in the design of this instrumentation is to develop the capacity to evaluate much larger areas of tissue. An approach to fulfilling this objective is the creation of a gasket that can seal individual wells of a nitrocellulose array. A gasket was created by laser cutting an assembly of molded silicone rubber and a double-sided tape (silicone-acrylic). Experiments showed when the gasket was adhered to a glass slide and subjected to the PCR, there was no leakage. FAST Slides, nitrocellulose slides provided by Grace Bio-Labs, are cut with a laser to generate the nitrocellulose arrays."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development of tissue printed nitrocellulose cards/arrays for real time PCR amplification and detection"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ian Hunter."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Chia, Helena Nien-Hwa, 1982-"],"dc:date.accessioned":["2006-05-15T20:33:02Z"],"dc:date.available":["2006-05-15T20:33:02Z"],"dc:date.issued":["2004"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2004.","Includes bibliographical references (leaf 21)."],"dc:description.abstract":["Tissue print technology allows for the transfer of cellular material from tissue onto a nitrocellulose film for immunocytochemical assays. The MIT BioInstrumentation Laboratory is currently developing a novel cancer marker imaging system for detection of cancerous tissue, which will be useful for discerning tumor margins. This research will advance the recent application of tissue print technology in bio-medicine by combining it with imaging and real time polymerase chain reaction (PCR) amplification and detection. A major objective in the design of this instrumentation is to develop the capacity to evaluate much larger areas of tissue. An approach to fulfilling this objective is the creation of a gasket that can seal individual wells of a nitrocellulose array. A gasket was created by laser cutting an assembly of molded silicone rubber and a double-sided tape (silicone-acrylic). Experiments showed when the gasket was adhered to a glass slide and subjected to the PCR, there was no leakage. FAST Slides, nitrocellulose slides provided by Grace Bio-Labs, are cut with a laser to generate the nitrocellulose arrays."],"dc:description.degree":["S.B."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/32828"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Development of tissue printed nitrocellulose cards/arrays for real time PCR amplification and detection"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:05Z"}