{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/32822"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/32822","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Design and testing of the thermal properties of the structure of an ultra high-throughput mutational spectrometer","abstract":"A process known as mutational spectrometry allows the detection of both single and multiple mutations that appear to be spontaneous, using a technique known as constant denaturing capillary electrophoresis (CDCE). CDCE requires a region of constant temperature and concentration of denaturant. A massively parallel, fully automated instrument, capable of handling as many as 10,000 DNA samples simultaneously, is suited to this technique. A modular structure of such a mutational spectrometer was designed to remain water-tight, provide an array to hold the capillaries for electrophoretic excitation, and modulate the flow of a heat transfer fluid. Six such modules were manufactured and assembled. As the heat transfer fluid passed through the assembled structure, the natural thermal loss was determined.","abstract_html":"A process known as mutational spectrometry allows the detection of both single and multiple mutations that appear to be spontaneous, using a technique known as constant denaturing capillary electrophoresis (CDCE). CDCE requires a region of constant temperature and concentration of denaturant. A massively parallel, fully automated instrument, capable of handling as many as 10,000 DNA samples simultaneously, is suited to this technique. A modular structure of such a mutational spectrometer was designed to remain water-tight, provide an array to hold the capillaries for electrophoretic excitation, and modulate the flow of a heat transfer fluid. Six such modules were manufactured and assembled. As the heat transfer fluid passed through the assembled structure, the natural thermal loss was determined.","abstract_has_math":false,"creators":["Del Zio, Michael R. (Michael Robert), 1982-"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Ian W. Hunter."],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004","date_published":"2004","updated_at":"2026-07-22T22:21:35Z","subjects":["Mechanical Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/32822","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ian W. Hunter."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Del Zio, Michael R. (Michael Robert), 1982-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-05-15T20:32:38Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-05-15T20:32:38Z"]},{"key":"dc:date.issued","label":"Date","values":["2004"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/32822"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2004.","Includes bibliographical references (leaves 42-43)."]},{"key":"dc:description.abstract","label":"Abstract","values":["A process known as mutational spectrometry allows the detection of both single and multiple mutations that appear to be spontaneous, using a technique known as constant denaturing capillary electrophoresis (CDCE). CDCE requires a region of constant temperature and concentration of denaturant. A massively parallel, fully automated instrument, capable of handling as many as 10,000 DNA samples simultaneously, is suited to this technique. A modular structure of such a mutational spectrometer was designed to remain water-tight, provide an array to hold the capillaries for electrophoretic excitation, and modulate the flow of a heat transfer fluid. Six such modules were manufactured and assembled. As the heat transfer fluid passed through the assembled structure, the natural thermal loss was determined."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Design and testing of the thermal properties of the structure of an ultra high-throughput mutational spectrometer"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ian W. Hunter."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Del Zio, Michael R. (Michael Robert), 1982-"],"dc:date.accessioned":["2006-05-15T20:32:38Z"],"dc:date.available":["2006-05-15T20:32:38Z"],"dc:date.issued":["2004"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2004.","Includes bibliographical references (leaves 42-43)."],"dc:description.abstract":["A process known as mutational spectrometry allows the detection of both single and multiple mutations that appear to be spontaneous, using a technique known as constant denaturing capillary electrophoresis (CDCE). CDCE requires a region of constant temperature and concentration of denaturant. A massively parallel, fully automated instrument, capable of handling as many as 10,000 DNA samples simultaneously, is suited to this technique. A modular structure of such a mutational spectrometer was designed to remain water-tight, provide an array to hold the capillaries for electrophoretic excitation, and modulate the flow of a heat transfer fluid. Six such modules were manufactured and assembled. As the heat transfer fluid passed through the assembled structure, the natural thermal loss was determined."],"dc:description.degree":["S.B."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/32822"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Design and testing of the thermal properties of the structure of an ultra high-throughput mutational spectrometer"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:35Z"}