Back to results

Massachusetts Institute of Technology

A spectroscopic and electrochemical study of chlorotitanates in molten salt media

Abstract

dc:description.abstract

Ultra-high purity titanium is used as a barrier metal in integrated circuitry. Metallothermic reduction does not produce titanium sufficiently pure for micro-electronics applications so electro refining of the metal in a molten chloride bath at temperatures above 700°C is necessary. The present study focused on the electrorefining of titanium in a bath consisting of the CsCl-NaCl-KCl eutectic as the solvent. Interfacial phenomena (multiple reaction steps and the kinetics associated with each) related to the faradaic process were investigated with electroanalytical techniques. The bulk chemistry of the electrolyte (the structure of the chlorotitanate complexes) that describes the nature of the species present during the electrorefining process was investigated using spectroscopic techniques. Recommendations were made concerning the potential for the various technologies to be used for on-line control to improve operating practices. Electrode kinetics were studied by ac voltammetry. Phase angle information was used to determine the value of the standard rate constant ([alpha) and the transfer coefficient (a) for the reduction couples Ti3+/Ti2+ and Ti2+/Ti0 at a glassy carbon electrode. The reduction from Ti2+ to metal has been identified as the slow step in the electrorefining process. The utility of electrochemical sensing to observe concentration changes has been judged poor. Industrial use of reference electrodes is recommended for controlling the overpotential in the electrorefining process and to improve efficiency. Absorption spectroscopy has established that a temperature sensitive equilibrium between TiC16 3- and TiCl4- exists in the CsCl-NaCl-KCl eutectic. Fiber optic absorption spectroscopy was shown to be capable of detecting additions of Ti2+ to melts containing Ti8+ , as well as sensing Ti3+ concentration fluctuations at a level of ±+5mM. Raman spectroscopy was found to be ill suited for investigating complexation in this system due to the deeply colored nature of the melts.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Materials Science and Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2000

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ortiz, Luis A. (Luis Anthony), 1974-
Advisor dc:contributor.advisor
  • Donald R. Sadoway.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/32702
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/32702

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Ortiz, Luis A. (Luis Anthony), 1974-. A spectroscopic and electrochemical study of chlorotitanates in molten salt media. Massachusetts Institute of Technology, 2000. http://hdl.handle.net/1721.1/32702