Back to results

Massachusetts Institute of Technology

Peripheral nerve regeneration through collagen devices with different in vivo degradation characteristics

Abstract

dc:description.abstract

In the United States more than 200,000 people are treated each year for peripheral nerve injuries that require surgery. Functional recovery of motor and sensory capability is limited following autograft, the most common procedure for peripheral nerve repair. Tubulation repair of a transected peripheral nerve presents an alternative to autograft, but has not yet shown the ability to satisfactorily restore lost function. A variety of degradable and non-degradable materials have been used to fabricate the tubes used to bridge the stumps of a transected nerve, and collagen tubes have been specifically shown to improve the quality of regeneration. The optimal characteristics for the tube have yet to be identified, and a collagen device that can be manipulated and optimized to improve functional peripheral nerve recovery is needed. The overall goal of this thesis was to fabricate and characterize a new collagen tube such that the tube characteristics and their effects on peripheral nerve regeneration can be closely studied, manipulated, and optimized. Following characterization of a homologous series of collagen tubes, each produced with a different density of crosslinks, the regenerative capacity of each member of the series of tubes was studied to determine the effects of device permeability, crosslink density, and in vivo tube degradation rate on peripheral nerve regeneration. It was first observed that the device permeability to cells and large soluble regulators significantly affected the quality of peripheral nerve regeneration, with the more permeable device (pore diameter 80 - 100 tm)

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2002

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Harley, Brendan A. (Brendan Andrew), 1978-
Advisor dc:contributor.advisor
  • Ioannis V. Yannas.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/32261
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/32261

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Harley, Brendan A. (Brendan Andrew), 1978-. Peripheral nerve regeneration through collagen devices with different in vivo degradation characteristics. Massachusetts Institute of Technology, 2002. http://hdl.handle.net/1721.1/32261