{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/31131"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/31131","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Spirasol : improvements to semi-continuous solar disinfection water treatment systems","abstract":"An experimental study was carried out to determine the feasibility of an original point of use solar water disinfection system created by the author and named \"Spirasol.\" The study primarily focused on the comparison of microbial removal levels in the Spirasol system and the more traditional solar disinfection method called SODIS that uses a Polyethylene Terephthalate (PET) bottle. To address microbial removal capacity, the two systems were assembled and tested in Nairobi, Kenya and later in Cambridge, Massachusetts. The issue of economic feasibility and component availability were also addressed and factored in heavily during the design phase of the project. The results suggest that the Spirasol system is equally as effective as the traditional SODIS system with respect to microbial inactivation. Analysis of the costs required for continuous and semi-continuous solar disinfection system implied that such systems were not a good match for sites of extreme urban poverty such as the Kibera slum in Nairobi, Kenya. However, the overall low cost among semi-continuous point of use treatment systems and the wide availability of the required pieces made them a sustainable technology for other areas in the developing world where available capital is marginally higher.","abstract_html":"An experimental study was carried out to determine the feasibility of an original point of use solar water disinfection system created by the author and named &quot;Spirasol.&quot; The study primarily focused on the comparison of microbial removal levels in the Spirasol system and the more traditional solar disinfection method called SODIS that uses a Polyethylene Terephthalate (PET) bottle. To address microbial removal capacity, the two systems were assembled and tested in Nairobi, Kenya and later in Cambridge, Massachusetts. The issue of economic feasibility and component availability were also addressed and factored in heavily during the design phase of the project. The results suggest that the Spirasol system is equally as effective as the traditional SODIS system with respect to microbial inactivation. Analysis of the costs required for continuous and semi-continuous solar disinfection system implied that such systems were not a good match for sites of extreme urban poverty such as the Kibera slum in Nairobi, Kenya. However, the overall low cost among semi-continuous point of use treatment systems and the wide availability of the required pieces made them a sustainable technology for other areas in the developing world where available capital is marginally higher.","abstract_has_math":false,"creators":["Loux, Brian Michael, 1981-"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Civil and Environmental Engineering.","school":null,"contributors":[],"advisors":["Peter Shanahan."],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005","date_published":"2005","updated_at":"2026-07-22T22:21:49Z","subjects":["Civil and Environmental Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/31131","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Peter Shanahan."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Civil and Environmental Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Civil and Environmental Engineering."]},{"key":"dc:creator","label":"Author","values":["Loux, Brian Michael, 1981-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-02-02T18:51:11Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-02-02T18:51:11Z"]},{"key":"dc:date.issued","label":"Date","values":["2005"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Civil and Environmental Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/31131"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2005.","Includes bibliographical references (leaves 60-63)."]},{"key":"dc:description.abstract","label":"Abstract","values":["An experimental study was carried out to determine the feasibility of an original point of use solar water disinfection system created by the author and named \"Spirasol.\" The study primarily focused on the comparison of microbial removal levels in the Spirasol system and the more traditional solar disinfection method called SODIS that uses a Polyethylene Terephthalate (PET) bottle. To address microbial removal capacity, the two systems were assembled and tested in Nairobi, Kenya and later in Cambridge, Massachusetts. The issue of economic feasibility and component availability were also addressed and factored in heavily during the design phase of the project. The results suggest that the Spirasol system is equally as effective as the traditional SODIS system with respect to microbial inactivation. Analysis of the costs required for continuous and semi-continuous solar disinfection system implied that such systems were not a good match for sites of extreme urban poverty such as the Kibera slum in Nairobi, Kenya. However, the overall low cost among semi-continuous point of use treatment systems and the wide availability of the required pieces made them a sustainable technology for other areas in the developing world where available capital is marginally higher."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.Eng."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Spirasol : improvements to semi-continuous solar disinfection water treatment systems"]}]}],"canonical_facts":{"dc:contributor.advisor":["Peter Shanahan."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Civil and Environmental Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Civil and Environmental Engineering."],"dc:creator":["Loux, Brian Michael, 1981-"],"dc:date.accessioned":["2006-02-02T18:51:11Z"],"dc:date.available":["2006-02-02T18:51:11Z"],"dc:date.issued":["2005"],"dc:description":["Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2005.","Includes bibliographical references (leaves 60-63)."],"dc:description.abstract":["An experimental study was carried out to determine the feasibility of an original point of use solar water disinfection system created by the author and named \"Spirasol.\" The study primarily focused on the comparison of microbial removal levels in the Spirasol system and the more traditional solar disinfection method called SODIS that uses a Polyethylene Terephthalate (PET) bottle. To address microbial removal capacity, the two systems were assembled and tested in Nairobi, Kenya and later in Cambridge, Massachusetts. The issue of economic feasibility and component availability were also addressed and factored in heavily during the design phase of the project. The results suggest that the Spirasol system is equally as effective as the traditional SODIS system with respect to microbial inactivation. Analysis of the costs required for continuous and semi-continuous solar disinfection system implied that such systems were not a good match for sites of extreme urban poverty such as the Kibera slum in Nairobi, Kenya. However, the overall low cost among semi-continuous point of use treatment systems and the wide availability of the required pieces made them a sustainable technology for other areas in the developing world where available capital is marginally higher."],"dc:description.degree":["M.Eng."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/31131"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Civil and Environmental Engineering."],"dc:title":["Spirasol : improvements to semi-continuous solar disinfection water treatment systems"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:49Z"}