Back to results

Massachusetts Institute of Technology

Design and analysis of wearable conductive fiber sensors for continuous multi-axis joint angle measurements

Abstract

dc:description.abstract

The practice of continuous, long-term monitoring of human joint motion is one that finds many applications, especially in the medical and rehabilitation fields. There is currently a lack of acceptable devices available to perform such measurements in an accurate and non-intrusive way for a patient over a long period of time, and so a new wearable sensor has been developed. A novel technique of incorporating conductive fibers into flexible, skin-tight fabrics surrounding a joint is used. Resistance changes across these conductive fibers are measured, and directly related to specific single or multi-axis joint angles through the use of a nonlinear predictor after an initial, one-time calibration. These wearable sensors are comfortable, and acceptable for long-term wear in everyday settings. Because these sensors are intended for multiple uses, an automated registration algorithm has been devised using a sensitivity template matched to an array of sensors spanning the joints of interest. In this way, a sensor array can be taken off and put back on an individual for multiple uses, with the sensors automatically calibrating themselves each time. Results have shown the feasibility of this type of sensor, with accurate measurements of joint motion for both a single-axis knee joint and a double axis hip joint when compared to a standard goniometer used to measure joint angles.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gibbs, Peter T., 1981-
Advisor dc:contributor.advisor
  • Haruhiko Harry Asada.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/30316
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/30316

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Gibbs, Peter T., 1981-. Design and analysis of wearable conductive fiber sensors for continuous multi-axis joint angle measurements. Massachusetts Institute of Technology, 2005. http://hdl.handle.net/1721.1/30316